Functional Units And Operations Performed - Texas Instruments TMS320C6000 Series Reference Manual

Table of Contents

Advertisement

Functional Units
2.2 Functional Units
Table 2–2. Functional Units and Operations Performed
Functional Unit
Fixed-Point Operations
.L unit (.L1,.L2)
32/40-bit arithmetic and compare operations
Leftmost 1 or 0 bit counting for 32 bits
Normalization count for 32 and 40 bits
32-bit logical operations
.S unit (.S1, .S2)
32-bit arithmetic operations
32/40-bit shifts and 32-bit bit-field operations
32-bit logical operations
Branches
Constant generation
Register transfers to/from the control register file
(.S2 only)
.M unit (.M1, .M2)
16
.D unit (.D1, .D2)
32-bit add, subtract, linear and circular address
calculation
Loads and stores with a 5-bit constant offset
Loads and stores with 15-bit constant offset
(.D2 only)
Note:
Fixed-point operations are available on both the 'C62x and the 'C67x. Floating-point operations and 32-bit fixed-point
multiply are available only on the 'C67x.
2-6
The eight functional units in the 'C62x/C67x data paths can be divided into two
groups of four; each functional unit in one data path is almost identical to the
corresponding unit in the other data path. The functional units are described
in Table 2–2.
16 bit multiply operations
Most data lines in the CPU support 32-bit operands, and some support long
(40-bit) operands. Each functional unit has its own 32-bit write port into a
general-purpose register file. All units ending in 1 (for example, .L1) write to
register file A and all units ending in 2 write to register file B. Each functional
unit has two 32-bit read ports for source operands src1 and src2 . Four units
(.L1, .L2, .S1, and .S2) have an extra 8-bit-wide port for 40-bit long writes, as
well as an 8-bit input for 40-bit long reads. Because each unit has its own 32-bit
write port, all eight units can be used in parallel every cycle.
Floating-Point Operations
Arithmetic operations
DP
SP, INT
DP, INT
conversion operations
Compare
Reciprocal and reciprocal square-
root operations
Absolute value operations
SP
DP conversion operations
32
32 bit fixed-point multiply
operations
Floating-point multiply operations
Load doubleword with 5-bit constant
offset
SP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tms320c67 seriesTms320c62 series

Table of Contents