Main Specifications
Signal Tower Connector
Pin assignment
CN
Signal name Description
(1)
+24 V
(2)
ERROR
(3)
READY
(4)
BUSY
* Off: This indicates the standby status, warning status, or a similar status. The machine cannot start printing
when it is in this status.
Connector assignment
2 3 4
Output specifications
Connect the lamp between the 24 V power supply (1) and (2), (3), and (4).
+24 V
GND
92
Chapter 3 Appendix
Power supply for the light, 50 mA max.
MotorError, ProtectMotorError, or temperature error.
Setup is complete and printing can start. When flashing, printing is paused.
Printing.
2 3 4
Power supply: +24 V (150 mA)
Output: Open collector
Output capacity: 50 mA max.