For the TN2312BP IPSI circuit packs to receive IP addresses dynamically, you first must assign
the switch ID and cabinet number to each IPSI circuit pack.The switch ID is a single letter, A
through J. The cabinet number is a 2-digit number, 01 through 64. For G650 Media Gateways, a
cabinet is defined as one or more media gateways connected by a TDM cable. This cabinet
configuration is called a G650-rack-mount-stack.
Note:
In the following procedure, you must start step 2 within 5 seconds after inserting
Note:
the circuit pack.
1. Fully insert the TN2312BP IPSI circuit pack. If necessary, reseat the circuit pack to start
the programming sequence.
Note:
For the following step, do not use a graphite pencil.
Note:
2. Insert a pen, golf tee, or similar object into the recessed push button switch.
Note:
If you pass the letter or number that you want, you have two options. You can
Note:
cycle through all the letters or numbers to get to the one you want. Or, you can
reinsert, or reseat, the circuit pack and start again.
Note:
If you have only one system, the default switch ID is A. The second system is B
Note:
and so on. The switch ID is not the media gateway or carrier letter.