Commissioning, service, troubleshooting
13.4 Troubleshooting
Event
Description
(alphabetical)
Status -
The motor feeder has been
cooling down
switched off due to overload.
period active
Status - DM-
Shows the status of the enabling
F enabling
circuit:
circuit
closed or
tripped
Status -
The thermal memory has been
emergency
cleared with the function
start
"Emergency start".
executed
Status - test
The motor feeder is in the test
position
position (TPF). The main circuit
(TPF)
has been interrupted and the
feeder can be "cold started".
Stop time >
The configured limit value for
motor stop time monitoring has
been exceeded.
Fault - bus
Bus communication has been or
is being interrupted.
Fault -
The PLC that controls the feeder
PLC/PCS
was or is in STOP mode.
Fault
The limit switches are not
antivalence
reporting any antivalent signals.
Fault -
A short circuit has occurred in the
EM open
wiring to the 3UL23 residual
circuit
current transformer.
Fault -
A short-circuit has occurred in
EM short-
the wiring to the 3UL23 residual
circuit
current transformer.
Fault end
Positioner/solenoid valve has left
position
the end position without a
command being issued. The
motor feeder has been turned off.
Fault -
One of the following components
temporary
is defective:
components
Memory module
(e.g. memory
PC cable.
module)
298
Troubleshooting
The motor can only be
switched on again after
the cooling down period
has expired.
The motor can be
switched on again
immediately after an
overload trip.
Please adopt the
maintenance measures
intended for the feeder. If
possible, switch on the
feeder.
Check the bus connection
(plugs, cables, etc.).
Check the operating state
of the PLC.
Limit switch open
circuit
Please check the
positioner application
and the limit switches.
Check the wiring to the
3UL23 residual current
transformer
Check the wiring to the
3UL23 residual current
transformer
Acknowledge the fault by
releasing with the counter
command
"OPEN/CLOSED".
Replace the defective
components. See Chapter
Replacing
SIMOCODE pro
components (Page 279).
System Manual, 05/2019, A5E40507475002A/RS-AD/004
Acknowledgment /
Contactor
fault rectification
control
Reset, auto-reset
Tripped
Reset, auto-reset
Tripped
Counter command
Tripped
"OPEN/CLOSED"
Reset
Tripped
Reset
Reset; counter
Tripped
command
Clear the fault;
Tripped
reset
Error
No.
1)
17
5
6
16
38
39
15
2
SIMOCODE pro