Siemens SIMOTICS CONNECT 400 Operating Instructions Manual
Siemens SIMOTICS CONNECT 400 Operating Instructions Manual

Siemens SIMOTICS CONNECT 400 Operating Instructions Manual

Connectivity module
Hide thumbs Also See for SIMOTICS CONNECT 400:
Table of Contents

Advertisement

Quick Links

www.siemens.com/digital-motor

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMOTICS CONNECT 400

  • Page 1 www.siemens.com/digital-motor...
  • Page 3 Safety instructions Description Preparations for use SIMOTICS CONNECT 400 Mounting and installation Commissioning Operating Instructions Operation Maintenance Disposal Further information SIMOTICS CONNECT 400 V1.0.2.0 SIDRIVE IQ Config (Android) V2.4.0 SIDRIVE IQ Config (iOS) V2.4.0 SIDRIVE IQ Fleet V2.10 04/2023 A5E50161952B AL...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    1.3.4 Websites of third-party companies..................10 SIMOTICS documentation ....................11 Service and Support......................12 1.5.1 Siemens Industry Online Support on the Web..............12 1.5.2 Siemens Industry Online Support on the road..............12 1.5.3 Feedback on the technical documentation ................. 13 1.5.4...
  • Page 6 Changing the measuring and send cycles ................. 124 7.2.4 Changing the device credentials of the connectivity module ..........126 7.2.5 Check asset data ......................127 Maintenance............................129 Updating the software and firmware (Android) ..............130 SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 7 Changing the attachment position of the mounting bracket ..........198 Disposal ............................. 199 Disposing of the connectivity module................200 Disposing of the battery....................201 Further information ........................... 203 10.1 Product information......................203 SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 8 Table of contents 10.2 Product support ....................... 204 10.3 Technical data........................206 10.4 Directives and standards ....................209 Index ..............................213 SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 9: Introduction

    Introduction About SIMOTICS Description SIMOTICS is the Siemens family of electric motors addressing the complete motor spectrum in Digital Industry. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 10: About Simotics (Detailed)

    In the meantime, our electric motors are an integral part of the digital enterprise. Motors for motion control Whether synchronous or induction, whether with or without gearbox: Siemens is the right partner when it involves the optimum motor for your motion control application.
  • Page 11: About This Manual

    This documentation does not contain all detailed information on all types of the product. Furthermore, this documentation cannot take into consideration every conceivable type of installation, operation and service/maintenance. The machine manufacturer must document any additions or modifications they make to the product themselves. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 12: Websites Of Third-Party Companies

    This document may contain hyperlinks to third-party websites. Siemens is not responsible for and shall not be liable for these websites and their content. Siemens has no control over the information which appears on these websites and is not responsible for the content and information provided there.
  • Page 13: Simotics Documentation

    Online help Instructions for configuring, program‐ Configuration engineers, program‐ ming, and commissioning mers, commissioning engineers Not all documentation classes are available for every SIMOTICS / SIMOGEAR / SINAMICS product. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 14: Service And Support

    Service and Support 1.5.1 Siemens Industry Online Support on the Web Description The following is available via Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/), among others: • Product support • Global forum for information and best practice sharing between users and specialists •...
  • Page 15: Feedback On The Technical Documentation

    1.5.3 Feedback on the technical documentation Description We welcome your questions, suggestions, and corrections for this technical documentation. Please use the "Provide feedback" link at the end of the entries in Siemens Industry Online Support. Figure 1-2 Requests and feedback SIMOTICS CONNECT 400...
  • Page 16: Mysupport Documentation

    • "Industry Online Support" mobile app The Support Request is the most important input channel for questions relating to products from Siemens Industry. This will assign your request a unique ticket number for tracking purposes. The Support Request offers you: •...
  • Page 17: Training

    Description SITRAIN – Digital Industry Academy offers a comprehensive range of training courses on Siemens industrial products – directly from the manufacturer, for all industries and use cases, for all knowledge levels from beginner to expert. More information can be found on the Internet via the following address (https:// www.siemens.com/sitrain).
  • Page 18: Important Product Information

    • Software developed by the OpenSSL project for use in the OpenSSL toolkit • Cryptographic software created by Eric Young. • Software developed by Eric Young You can find more information on the internet: • OpenSSL (https://www.openssl.org) • Cryptsoft (https://www.cryptsoft.com) SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 19: Compliance With The General Data Protection Regulation

    1.6.3 Compliance with the General Data Protection Regulation Description Siemens complies with the principles of the General Data Protection Regulation (EU), in particular the principle of data minimization (privacy by design). For this SINAMICS product, this means: • User management and access control (UMAC) The product processes or stores the following personal data: –...
  • Page 20 The creator of the library must anonymize or pseudonymize the login data by selecting suitable user names. Our product does not provide any functions for automatically deleting personal data. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 21: Safety Instructions

    • Do not short-circuit the battery. • Do not connect the battery with the incorrect polarity. • Do not heat up the battery to over 100 °C. • Protect the battery from direct solar radiation, humidity and condensation. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 22: Qualified Personnel

    • Through appropriate training and experience, they are able to recognize and avoid risks and potential dangers in their particular field of activity. • Those responsible have instructed them to carry out the work. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 23: Security Information

    (https://www.siemens.com/industrialsecurity). Specific security information for SC400 • Make sure that the Bluetooth range of SIMOTICS CONNECT 400 does not extend outside of the company site (approx. 5-10 meters). • Make sure that the Wi-Fi is used with awareness of security issues. This includes using the WPA2 security protocol.
  • Page 24 Safety instructions 2.3 Security information SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 25: Description

    SIDRIVE IQ Fleet SIMOTICS CONNECT 400 connects drive train components with the cloud-based analytics of the SIDRIVE IQ Fleet MindSphere application. This enables you to improve the productivity, reliability, and service options of the drive train component.
  • Page 26: Simotics Connect 400" Connectivity Module

    The captured motor data are transmitted to SIDRIVE IQ Fleet via a Wi-Fi interface and analyzed. Note The SIMOTICS CONNECT 400 connectivity module can be used in combination with rib-cooled low-voltage induction motors (see Technical specifications (Page 206)). In addition to motor monitoring, from V1.0.2.0, "Generic Vibration monitoring" can be set.
  • Page 27 Description 3.2 "SIMOTICS CONNECT 400" connectivity module The Connectivity Kit contains the following components in addition to the connectivity module: • Metal bracket for mounting on the motor housing • Fastening screws Data security The data are backed up using the following mechanisms: •...
  • Page 28 Description 3.2 "SIMOTICS CONNECT 400" connectivity module SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 29: Preparations For Use

    Preparations for use Visual inspection After mounting the motor, visually inspect the connectivity module for any damage. In case of damage, please contact Product Support (Page 204). SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 30: Shipping And Storage Conditions

    Do not damage the connectivity module while the motor is being transported, stored and operated. It is not permissible that the connectivity module is subject to mechanical loads and stress. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 31: Requirements

    The SIMOTICS CONNECT 400 connectivity module does not support Wi-Fi authentication protocols according to IEEE 802.1X. Ports that are used Release the following ports used by SIMOTICS CONNECT 400 to allow an Internet connection to be established: • Secure data exchange with SIDRIVE IQ Fleet: TCP port 443 •...
  • Page 32 Preparations for use 4.3 Requirements SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 33: Mounting And Installation

    If the ambient conditions according to IP54 cannot be ensured at the installation location – or if a higher degree of protection is required – then the user must apply additional measures to ensure safe and reliable operation. With production version ≥ FS03, SIMOTICS CONNECT 400 housings have an IP65 degree of protection. Requirement Upgrade your motor with a connectivity module.
  • Page 34: Installing The Mounting Bracket

    Short arm of the mounting bracket: Inner side for gluing to the motor cooling ribs over the full surface area ② Thread for the fastening screws of the connectivity module ③ Long arm of the mounting bracket: Surface for attaching the connectivity module using screws ④ Thermally conducting contact SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 35 2. Choose the position for the connectivity module on the motor. The following figures show examples of the position for the connectivity module on the motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 36 5. Press the mounting bracket onto the motor cooling ribs using your hand. 6. Allow the adhesive applied to the mounting bracket to dry. Carefully comply with the usage instructions provided on the adhesive package. 7. Allow the adhesive to completely dry. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 37: Mounting The Connectivity Module

    The battery is not contacted in the delivered condition. Mounting elements The following figures provide an overview of the relevant mounting elements of the connectivity module in the closed and open condition: ① Front cover ② Cover fastening screws SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 38 The LED display of the connectivity module may light up for longer than 40 seconds for the battery test. 7. Put the front cover back in position. Ensure that the cover fits precisely. 8. Tighten the 2 central fastening screws at the front cover by hand. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 39: Commissioning

    • The mobile device has an Internet connection via Wi-Fi or GSM/LTE • There is a Wi-Fi access point to connect the connectivity module to the Internet. • You have valid access data for "SIDRIVE IQ Fleet". SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 40: Commissioning With Android

    1. Open the Google Play Store. (https://play.google.com/store/apps/details? id=com.siemens.configapp) 2. Install the Siemens "SIDRIVE IQ Config" application. After the first start of the application, the terms of use are displayed once. Take note of them and click "Accept" to confirm. The "SIDRIVE IQ Config" application requires the following access authorizations: –...
  • Page 41 If necessary, confirm a pairing request to establish the Bluetooth connection. Procedure 1. Open the "SIDRIVE IQ Config" application. 2. Select an asset. 3. Tap on the ">" button to establish a connection to the connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 42: Log In With The Connectivity Module

    Change the user name and password after logging on for the first time for protection against unauthorized access to the connectivity module. In the "Device Credentials" step of the commissioning wizard, you are requested to change the login data. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 43 3. After 5 unsuccessful attempts with an invalid user name or an invalid password, for security reasons, the login is locked for 3 minutes. You can then attempt to log in again. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 44 This function requires additional entry of the Wi-Fi password. This ensures that only authorized persons can reset the user login information. If the Wi-Fi has not yet been configured in SC400, the "Wi-Fi password" field must remain empty. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 45: Guided Commissioning

    You are logged in to the connectivity module via the "SIDRIVE IQ Config" application. Procedure 1. Start the commissioning wizard with the "Commission" button. 6.2.4.2 Device Credentials - Step 1/7 Change the login data for protection against unauthorized access to the connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 46 – At least one uppercase letter (A-Z) – At least one lowercase letter (a-z) – At least one numeral (0-9) – The following special characters are permitted: Hyphens (-) and underscores (_) are allowed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 47: Wi-Fi - Step 2/7

    Connect the connectivity module to the Wi-Fi network. Supported Wi-Fi networks The current version of the SIMOTICS CONNECT 400 connectivity module does not support proxy server configuration. The connectivity module encrypts your data according to security standard WPA2. For data transfer, the connectivity module supports Wi-Fi connections with a frequency of 2.4 GHz...
  • Page 48: Firmware - Step 3/7

    6.2.4.4 Firmware - Step 3/7 To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. The firmware is provided by Siemens as a file in "*.bin" format. Note...
  • Page 49 • The Wi-Fi network allows communication between the participants, i.e. between the connectivity module and the mobile device. • Load the latest firmware version onto your mobile device. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 50 The LED goes dark after the firmware has been updated. The connectivity module automatically restarts after the firmware has been successfully updated. 3. Log on again after the connectivity module has restarted and restart the commissioning wizard. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 51: Intervals - Step 4/7

    • 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet" You can modify these settings within a preset range of 1 to 48 hours. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 52: Mindsphere Access - Step 5/7

    In the following step, you establish the MindSphere access for onboarding. The process applied from connecting and registering the connectivity module through to the MindSphere application "SIDRIVE IQ Fleet", including all settings, is called onboarding. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 53 1. Enter the MindSphere tenant name in the "Tenant name" field. The length is limited to 8 characters. If you have received a special URL from Siemens for onboarding, enter it in the "Tenant name" field. Start entering the URL with "https://".
  • Page 54 It is possible that the Recognize text / Word suggestions function of your mobile device enters a blank at the end of the email address that is entered. Delete this blank before logging in. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 55: Motor Details - Step 6/7

    If the connectivity module is retrofitted or replaced with a replacement device, the serial number and the product article number of the motor must be reassigned. This operation SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 56 In addition to motor monitoring, from V1.0.2.0, "Generic Vibration monitoring" can be set. Using this function, additional components of the drive train can be monitored, for example, gearbox, coupling, pillow block bearing, pump, fan, compressor as well as other rotating and non-rotating parts. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 57 Scan the data matrix code of the motor by tapping the "Scan data matrix code" button. Note Motor assignment by scanning the data matrix code is only possible if the Siemens motor has been provided with a 2D code. SIMOTICS CONNECT 400...
  • Page 58 This applies both to Siemens motors and to motors of other manufacturers. Proceed as described below to create a new motor data set.
  • Page 59 Commissioning 6.2 Commissioning with Android Creating a new motor data set is explained using the following rating plate as example. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 60 Mindsphere application "SIDRIVE IQ Fleet". Note Mandatory fields The input fields marked "*" are mandatory fields. Note Text color in input fields black = predefined values can be overwritten gray = expected input format SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 61 Commissioning 6.2 Commissioning with Android SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 62 For this, besides current, you can also enter values for speed, efficiency, and power factor. Gaps in the data are permitted, however: The more data you enter, the more accurately you will be able to determine the operating point. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 63 Commissioning 6.2 Commissioning with Android Note Shaft height If the shaft height is not stated on the rating plate, you must measure the shaft height. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 64: Asset Info (Motor Monitoring) - Step 7/7

    Asset Info (Motor Monitoring) - Step 7/7 Note Settings cannot be modified subsequently Select the following settings carefully. There is no way of modifying the settings after selection. If you choose an incorrect setting, repeat the onboarding process. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 65 Choose an asset name to which the asset can be uniquely assigned in "SIDRIVE IQ Fleet". Avoid using asset names that have already been used. – Asset description – Location 2. Select the application type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 66 Commissioning 6.2 Commissioning with Android 3. Select the operating point. If there are multiple parameter sets in the rating data, select the parameter set that matches the connection conditions of your motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 67 When selecting "direct-on-line operation (DOL)", you can immediately continue with step 7. When selecting "variable speed drive (VSD)", the following additional fields are displayed. – VSD operating mode – Inverter input voltage (V) – Inverter output voltage (V) SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 68 If you are not certain when making the selection, or if the converter is not operated in one of the specified control modes, then select U/f. 6. Enter the inverter input voltage (V). The inverter output voltage (V) is determined when entering the inverter input voltage. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 69 IQ Fleet", which means that you can see the actual connection status shortly after commissioning. The connectivity module automatically starts the calibration procedure on the motor. It requires 10 measuring cycles with the motor in the "ON" state and 10 measuring cycles with SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 70 These provisions do not result in any additional costs for your account. All costs are already included in the SIDRIVE IQ Fleet Asset package that you purchased. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 71: Asset Info (Generic Vibration Monitoring) - Step 7/7

    Choose an asset name to which the asset can be uniquely assigned in "SIDRIVE IQ Fleet". Avoid using asset names that have already been used. – Asset description – Location 2. Select the device type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 72 Commissioning 6.2 Commissioning with Android 3. Select the application type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 73 Commissioning 6.2 Commissioning with Android 4. Enter the input speed and the output speed. Fields Speed In (rpm) and Speed Out (rpm) are only displayed for a Gearbox device type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 74 After commissioning has been completed, you are automatically logged off from the device and the Bluetooth connection is disconnected. The connectivity module starts to record data and transfer data in the preselected intervals. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 75 These provisions do not result in any additional costs for your account. All costs are already included in the SIDRIVE IQ Fleet Asset package that you purchased. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 76: Commissioning With Ios

    Installing the "SIDRIVE IQ Config" application 1. Open the App Store (https://apps.apple.com/de/app/sidrive-iq-config/id1578297088). 2. Install the Siemens "SIDRIVE IQ Config" application. After the first start of the application, the terms of use are displayed once. Take note of them and click "Accept" to confirm.
  • Page 77 Note: Replace the battery in good time. If disturbances occur in data transmission, replace the batteries (Page 196). ⑦ Button for opening help ⑧ Button for establishing a connection to the connectivity module If necessary, confirm a pairing request to establish the Bluetooth connection. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 78 "SIDRIVE IQ Config". For Bluetooth pairing with PIN input, follow the instructions in the following section. Note If an older firmware version is installed on your connectivity module, we recommend performing a firmware update. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 79 2. To scan, hold the camera of your mobile device over the 2D code on the left at the top of the connectivity module. 3. If scanning was successful, "SIDRIVE IQ Config" displays the Bluetooth pairing PIN and copies it to the clipboard. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 80: Log In With The Connectivity Module

    Change the user name and password after logging on for the first time for protection against unauthorized access to the connectivity module. In the "Device Credentials" step of the commissioning wizard, you are requested to change the login data. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 81: Guided Commissioning

    Starting the commissioning wizard The commissioning wizard guides you step by step through the commissioning of the connectivity module. Note Commissioning wizard - Help For each commissioning step, you can call help with the icon. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 82: Device Credentials - Step 1/7

    You are logged in to the connectivity module via the "SIDRIVE IQ Config" application. Procedure 1. Start the commissioning wizard with the "Commission" button. 6.3.4.2 Device Credentials - Step 1/7 Change the login data for protection against unauthorized access to the connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 83 – At least one uppercase letter (A-Z) – At least one lowercase letter (a-z) – At least one numeral (0-9) – The following special characters are permitted: Hyphens (-) and underscores (_) are allowed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 84: Wi-Fi - Step 2/7

    Connect the connectivity module to the Wi-Fi network. Supported Wi-Fi networks The current version of the SIMOTICS CONNECT 400 connectivity module does not support proxy server configuration. The connectivity module encrypts your data according to security standard WPA2. For data transfer, the connectivity module supports Wi-Fi connections with a frequency of 2.4 GHz...
  • Page 85: Firmware - Step 3/7

    6.3.4.4 Firmware - Step 3/7 To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. The firmware is provided by Siemens as a file in ".bin" format. Note...
  • Page 86 • The Wi-Fi network allows communication between the participants, i.e. between the connectivity module and the mobile device. • Load the latest firmware version onto your mobile device. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 87 If you restart the commissioning wizard within five minutes of disconnecting the Bluetooth connection, commissioning will be resumed at Step 4/7 - Intervals. If the Bluetooth connection is disconnected for longer than 5 minutes, start commissioning at Step 1/7 - Device Credentials. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 88: Intervals - Step 4/7

    • 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet" You can modify these settings within a preset range of 1 to 48 hours. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 89: Mindsphere Access - Step 5/7

    In the following step, you establish the MindSphere access for onboarding. The process applied from connecting and registering the connectivity module through to the MindSphere application "SIDRIVE IQ Fleet", including all settings, is called onboarding. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 90 1. Enter the MindSphere tenant name in the "Tenant name" field. The length is limited to 8 characters. If you have received a special URL from Siemens for onboarding, enter it in the "Tenant name" field. Start entering the URL with "https://".
  • Page 91: Motor Details - Step 6/7

    If the connectivity module is retrofitted or replaced with a replacement device, the serial number and the product article number of the motor must be reassigned. This operation SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 92 In addition to motor monitoring, from V1.0.2.0, "Generic Vibration monitoring" can be set. Using this function, additional components of the drive train can be monitored, for example, gearbox, coupling, pillow block bearing, pump, fan, compressor as well as other rotating and non-rotating parts. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 93 Scan the "Data Matrix Code" of the motor by tapping the "Scan Data Matrix" button. Note Motor assignment by scanning the data matrix code is only possible if the Siemens motor has been provided with a 2D code. SIMOTICS CONNECT 400...
  • Page 94 This applies both to Siemens motors and to motors of other manufacturers. Proceed as described below to create a new motor data set.
  • Page 95 Commissioning 6.3 Commissioning with iOS SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 96 Mindsphere application "SIDRIVE IQ Fleet". Note Mandatory fields The input fields marked "*" are mandatory fields. Note Text color in input fields black = predefined values can be overwritten gray = expected input format SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 97 Commissioning 6.3 Commissioning with iOS SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 98 For this, besides current, you can also enter values for speed, efficiency, and power factor. Gaps in the data are permitted, however: The more data you enter, the more accurately you will be able to determine the operating point. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 99 Commissioning 6.3 Commissioning with iOS Note Shaft height If the shaft height is not stated on the rating plate, you must measure the shaft height. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 100: Asset Info (Motor Monitoring) - Step 7/7

    2. Check the data entered and confirm with the "Send" button. 3. Continue to commission the equipment. 6.3.4.8 Asset Info (Motor Monitoring) - Step 7/7 Enter the asset data in the last step of the commissioning wizard. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 101 Choose an asset name to which the asset can be uniquely assigned in SIDRIVE IQ Fleet. Avoid using asset names that have already been used. – Asset description – Location 2. Select the application type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 102 Commissioning 6.3 Commissioning with iOS 3. Select the operating point. If there are multiple parameter sets in the rating data, select the parameter set that matches the connection conditions of your motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 103 When selecting "direct-on-line operation (DOL)", you can immediately continue with step 7. When selecting "variable speed drive (VSD)", the following additional fields are displayed. – VSD operating mode – Inverter input voltage (V) – Inverter output voltage (V) SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 104 If you are not certain when making the selection, or if the converter is not operated in one of the specified control modes, then select U/f. 6. Enter the inverter input voltage (V). The inverter output voltage (V) is determined when entering the inverter input voltage. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 105 IQ Fleet, which means that you can see the actual connection status shortly after commissioning. The connectivity module automatically starts the calibration procedure on the motor. It requires 10 measuring cycles with the motor in the "ON" state and 10 measuring cycles with SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 106: Asset Info (Generic Vibration Monitoring) - Step 7/7

    SIDRIVE IQ Fleet Asset package that you purchased. 6.3.4.9 Asset Info (Generic Vibration monitoring) - Step 7/7 Enter the asset data in the last step of the commissioning wizard. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 107 Choose an asset name to which the asset can be uniquely assigned in SIDRIVE IQ Fleet. Avoid using asset names that have already been used. – Asset description – Location 2. Select the device type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 108 Commissioning 6.3 Commissioning with iOS 3. Select the application type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 109 4. Enter the input speed and the output speed. Fields Speed In (rpm) and Speed Out (rpm) are only displayed for a Gearbox device type. 5. Exit step 7/7 using the "Finish" button. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 110 These provisions do not result in any additional costs for your account. All costs are already included in the SIDRIVE IQ Fleet Asset package that you purchased. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 111: Operation

    "Generic Vibration monitoring", the following icons are displayed in the dashboard view: Motor Monitoring Generic Vibration monitoring Note: For "Generic Vibration monitoring", functions Motor Data and Replace Mo‐ tor are not shown. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 112: Operation With Android

    • You have logged onto the connectivity module (Page 40). • The Wi-Fi connection has been set up. • The SIMOTICS Connect 400 connectivity module is registered with IQFleet. • You have the role "iqfleet.offboarding" in "SIDRIVE IQ Fleet". If you do not have this role, offboarding is canceled with an error message "Insufficient rights".
  • Page 113 Operation 7.1 Operation with Android Procedure 1. Select "Delete asset (Offboarding)" in the dashboard view. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 114: Logging In To Mindsphere

    It is possible that the Recognize text / Word suggestions function of your mobile device enters a blank at the end of the email address that is entered. Delete this blank before logging in. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 115 You remain logged in to the MindSphere tenant as long as you continue to use the "SIDRIVE IQ Config" application You are automatically logged off from MindSphere when you close the application. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 116: Executing The Offboarding Process

    Each connectivity module has a blue LED display in the front cover. The LED display is used to visually identify the connectivity module that is currently connected to "SIDRIVE IQ Config" more easily. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 117: Changing The Measuring And Send Cycles

    You can change these settings within a specified range of between 1 and 48 hours. Note Effects that influence the battery life Shorter intervals result in a shorter battery life. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 118 7.1 Operation with Android Procedure 1. In the dashboard view, select "Intervals". 2. Change the measuring cycle. The "Calculated battery life" is updated. 3. Change the send cycle. The "Calculated battery life" is updated. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 119: Changing The User Data Of The Connectivity Module

    7.1.4 Changing the user data of the connectivity module 1. In the dashboard view, select "Device credentials". 2. Change the user names. The user name must not comprise more than 21 characters. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 120: Check Asset Data

    4. Enter the new password again in the "Repeat password" field. 5. Confirm your changes by pressing "Apply" The user data are changed. 7.1.5 Check asset data After onboarding, you can display the asset data stored in the connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 121 Operation 7.1 Operation with Android Procedure Select "Asset Info" in the dashboard view. The "Asset Info" dialog opens. The values displayed cannot be changed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 122 Operation 7.1 Operation with Android SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 123: Operation With Ios

    • You have logged onto the connectivity module (Page 78). • The Wi-Fi connection has been set up. (Page 82) • The SIMOTICS Connect 400 connectivity module is registered with IQFleet. (Page 98) • You have the role "iqfleet.offboarding" in "SIDRIVE IQ Fleet". If you do not have this role, offboarding is canceled with an error message "Insufficient rights".
  • Page 124 Operation 7.2 Operation with iOS Procedure 1. Select "Delete asset (Offboarding)" in the dashboard view. 2. Confirm initiation of the offboarding process with "Yes". SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 125: Identifying The Connectivity Module Via The "Sidrive Iq Config" Application

    Each connectivity module has a blue LED display in the front cover. The LED display is used to visually identify the connectivity module that is currently connected to "SIDRIVE IQ Config" more easily. Use the "Identify" function to check that you are connected with the required connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 126: Changing The Measuring And Send Cycles

    You can change these settings within a specified range of between 1 and 48 hours. Note Effects that influence the battery life Shorter intervals result in a shorter battery life. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 127 7.2 Operation with iOS Procedure 1. In the dashboard view, select "Intervals". 2. Change the measuring cycle. The "Calculated battery life" is updated. 3. Change the send cycle. The "Calculated battery life" is updated. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 128: Changing The Device Credentials Of The Connectivity Module

    7.2.4 Changing the device credentials of the connectivity module 1. In the dashboard view, select "Device credentials". 2. Change the user names. The user name must not comprise more than 21 characters. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 129: Check Asset Data

    4. Enter the new password again in the "Repeat password" field. 5. Confirm your changes by pressing "Apply" The user data are changed. 7.2.5 Check asset data After onboarding, you can display the asset data stored in the connectivity module. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 130 Operation 7.2 Operation with iOS Procedure Select "Asset Info" in the dashboard view. The "Asset Info" dialog opens. The values displayed cannot be changed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 131: Maintenance

    "Generic Vibration monitoring", the following icons are displayed in the dashboard view: Motor Monitoring Generic Vibration monitoring Note: For "Generic Vibration monitoring", functions Motor Data and Replace Mo‐ tor are not shown. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 132: Updating The Software And Firmware (Android)

    To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. Update the firmware using the "SIDRIVE IQ Config" application. You will find the latest firmware version at Siemens Industry Online Support (SIOS) (https:// support.industry.siemens.com/cs/de/en/ps/25522/dl).
  • Page 133 This is necessary to avoid loss of data. Then continue with the following steps. 4. In the dashboard view, under "Commissioning settings", select function "Firmware". 5. Tap on the "Update" button. The Android File Picker opens. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 134 6. Select the file that is locally on your mobile device, and confirm the transfer. The firmware is provided by Siemens as a file in ".bin" format. 7. In the following dialog, click on "OK" to start the update. A progress bar is displayed while the firmware file is being transferred.
  • Page 135: Updating Software And Firmware (Ios)

    Updating the connectivity module firmware (iOS) To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. The firmware is provided by Siemens as a file in "*.bin" format.
  • Page 136 LED on the front of the connectivity module first flashes slowly – and then faster. The LED goes dark after the firmware has been updated. The connectivity module automatically restarts after the firmware has been successfully updated. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 137: Basic Functions (Android)

    The new motor is continually monitored under the existing asset name. Data previously saved in SIDRIVE IQ Fleet are not deleted. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 138 This function requires additional entry of the Wi-Fi password. This ensures that only authorized persons can reset the user login information. If the Wi-Fi has not yet been configured in SC400, the "Wi-Fi password" field must remain empty. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 139: Basic Functions (Ios)

    Offboarding is the precondition for a new commissioning process (onboarding) to "SIDRIVE IQ Fleet". Send data to Mind‐ Starts transfer of the measurement data from the memory of the connectivity module to "SI‐ Sphere DRIVE IQ Fleet". Precondition: The onboarding process has already been performed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 140 If the Wi-Fi has not yet been configured in SC400, the "Wi-Fi password" field must remain empty. Identification Helps you to visually identify the currently connected connectivity module. The connectivity module LED flashes for five seconds. (press the motor sym‐ bol) SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 141: Replacing The Connectivity Module

    8. Insert the battery connector. 9. Put the front cover back in position. Ensure that the cover fits precisely. 10.Tighten the 2 central fastening screws at the front cover by hand. 11.Reconfigure the connectivity module (Page 37). SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 142: Commissioning The Connectivity Module After Hardware Replacement (Android)

    8.5.2.1 Starting the module replacement wizard Using function "Replace Module", you can replace a SIMOTICS Connect 400 connectivity module by a new one. This means that you can still monitor your motor, which was already registered in SIDRIVE IQ Fleet, without losing any historical data.
  • Page 143 – At least one uppercase letter (A-Z) – At least one lowercase letter (a-z) – At least one numeral (0-9) – The following special characters are permitted: Hyphens (-) and underscores (_) are allowed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 144: Wi-Fi - Step 2/7

    Connect the connectivity module to the Wi-Fi network. Supported Wi-Fi networks The current version of the SIMOTICS CONNECT 400 connectivity module does not support proxy server configuration. The connectivity module encrypts your data according to security standard WPA2. For data transfer, the connectivity module supports Wi-Fi connections with a frequency of 2.4 GHz...
  • Page 145: Firmware - Step 3/7

    8.5.2.4 Firmware - Step 3/7 To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. The firmware is provided by Siemens as a file in ".bin" format. Note...
  • Page 146 • The Wi-Fi network allows communication between the participants, i.e. between the connectivity module and the mobile device. • Load the latest firmware version onto your mobile device. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 147 3. Log on again after the connectivity module has restarted and restart the module replacement wizard and skip steps 1/7, 2/7 and 3/7. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 148: Intervals - Step 4/7

    • 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet" You can modify these settings within a preset range of 1 to 48 hours. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 149: Mindsphere Access - Step 5/7

    In the following step, you establish the MindSphere access for onboarding. The process applied from connecting and registering the connectivity module through to the MindSphere application "SIDRIVE IQ Fleet", including all settings, is called onboarding. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 150 1. Enter the MindSphere tenant name in the "Tenant name" field. The length is limited to 8 characters. If you have received a special URL from Siemens for onboarding, enter it in the "Tenant name" field. Start entering the URL with "https://".
  • Page 151 It is possible that the Recognize text / Word suggestions function of your mobile device enters a blank at the end of the email address that is entered. Delete this blank before logging in. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 152 5. Confirm your entry of the login data with the "Sign In" button. The "Login" button is deactivated in the commissioning wizard once you have successfully logged in. 6. Move on to the next step with the "Next" button. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 153: Asset Overview - Step 6/7

    Asset Overview - Step 6/7 After you have logged in to SIDRIVE IQ Fleet, in Step "Asset Overview" you can see the list of all assets that are integrated in the tenant. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 154 Procedure 1. From the list, select the asset that you wish to connect to the new connectivity module. – If the Siemens motor has a 2D code, you can assign the motor by scanning the "Data Matrix Code". Press the Scan button. The corresponding asset is automatically selected from the list of assets.
  • Page 155: Replacement Reason - Step 7/7

    Replacement reason (motor monitoring) - Step 7/7 (Page 153) or Replacement reason (Generic Vibration monitoring) - Step 7/7. 8.5.2.8 Replacement reason - Step 7/7 In the last step of the module replacement wizard, enter the reason for the replacement. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 156 Maintenance 8.5 Replacing the connectivity module Procedure 1. Under "Reason of replacement", open the drop-down list. 2. From the following list, select the reason why the module was replaced. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 157 3. When selecting "Other" you have the option of entering a reason for the replacement in the "Comment" field. 4. Start the replacement process using the "Next" button. The progress of the replacement process is displayed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 158 "operating state" signal after the calibration process: Value "0": Motor off (OFF), sensor calibrated Value "1": Motor status not defined, sensor not calibrated Value "3": Motor on (ON), sensor calibrated No additional measures are required to support calibration. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 159: Commissioning The Connectivity Module After Hardware Replacement (Ios)

    8.5.3.1 Starting the module replacement wizard You can replace a SIMOTICS Connect 400 connectivity module by a new one using function "Replace Module". This means that you can still monitor your motor, which was already registered in SIDRIVE IQ Fleet, without losing any historical data.
  • Page 160 – At least one uppercase letter (A-Z) – At least one lowercase letter (a-z) – At least one numeral (0-9) – The following special characters are permitted: Hyphens (-) and underscores (_) are allowed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 161: Wi-Fi - Step 2/7

    Connect the connectivity module to the Wi-Fi network. Supported Wi-Fi networks The current version of the SIMOTICS CONNECT 400 connectivity module does not support proxy server configuration. The connectivity module encrypts your data according to security standard WPA2. For data transfer, the connectivity module supports Wi-Fi connections with a frequency of 2.4 GHz...
  • Page 162: Firmware - Step 3/7

    8.5.3.4 Firmware - Step 3/7 To keep the firmware of the connectivity module up to date and to implement new functions, firmware updates are regularly made available. The firmware is provided by Siemens as a file in ".bin" format. Note...
  • Page 163 • The Wi-Fi network allows communication between the participants, i.e. between the connectivity module and the mobile device. • Load the latest firmware version onto your mobile device. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 164 Bluetooth connection, module replacement will be resumed at Step 4/7 - Intervals. If the Bluetooth connection is disconnected for longer than 5 minutes, start the module replacement and skip steps 1/7, 2/7 and 3/7. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 165: Intervals - Step 4/7

    • 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet" You can modify these settings within a preset range of 1 to 48 hours. Note To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 166: Mindsphere Access - Step 5/7

    In the following step, you establish the MindSphere access for onboarding. The process applied from connecting and registering the connectivity module through to the MindSphere application "SIDRIVE IQ Fleet", including all settings, is called onboarding. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 167 1. Enter the MindSphere tenant name in the "Tenant name" field. The length is limited to 8 characters. If you have received a special URL from Siemens for onboarding, enter it in the "Tenant name" field. Start entering the URL with "https://".
  • Page 168 Delete this blank before logging in. 5. Confirm your entry of the login data with the "Sign In" button. After successfully logging in, you go directly to Step 6 - Asset Overview. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 169: Asset Overview - Step 6/7

    8.5.3.7 Asset Overview - Step 6/7 After you have logged into SIDRIVE IQ Fleet, in Step "Asset Overview", you can see the list of all assets that are integrated in the tenant. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 170 Procedure 1. From the list, select the asset that you wish to connect to the new connectivity module. – If the Siemens motor has a 2D code, you can assign the motor by scanning the "Data Matrix Code". Press the Scan button. The corresponding asset is automatically selected from the list of assets.
  • Page 171: Replacement Reason - Step 7/7

    2. Move on to the next step with the "Next" button. 8.5.3.8 Replacement reason - Step 7/7 In the last step of the module replacement wizard, enter the reason for the replacement. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 172 Maintenance 8.5 Replacing the connectivity module Procedure 1. Press on > . 2. From the following list, select the reason why the module was replaced. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 173 Maintenance 8.5 Replacing the connectivity module 3. When selecting "Other" you have the option of entering a reason for the replacement in the "Comment" field. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 174 Maintenance 8.5 Replacing the connectivity module 4. Accept the selection, and confirm using the "Finish" button. 5. Start the replacement process using the "Replace Module" button. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 175 "operating state" signal after the calibration process: Value "0": Motor off (OFF), sensor calibrated Value "1": Motor status not defined, sensor not calibrated Value "3": Motor on (ON), sensor calibrated No additional measures are required to support calibration. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 176: Replacing A Motor (Android)

    • You are logged in to the connectivity module via the "SIDRIVE IQ Config" application. • The Wi-Fi connection has been set up. • The SIMOTICS Connect 400 connectivity module is registered with SIDRIVE IQ Fleet. • You have the necessary authorization (see operating instructions, SIDRIVE IQ Fleet, Section Activate MindSphere user account >...
  • Page 177: Mindsphere Access

    The login dialog for MindSphere is displayed after starting the motor replacement wizard. Note The tenant name is used under which the asset is registered. It is not possible to change the tenant. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 178: Replacement Reason - Step 1/3

    3. After you have successfully logged in, transition to the next step using the "Next" button. 8.6.3 Replacement reason - Step 1/3 In Step 1 - Replacement information, enter the reason why the motor is being replaced. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 179: New Motor Data - Step 2/3

    In the following step, use the serial number and manufacturer's article number of the new motor. If you have not replaced the motor, but for instance you have only changed the operating mode, then you can use the data of the "old" motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 180 Scan the "Data Matrix Code" of the motor by tapping the "Scan Data Matrix" button. Note Motor assignment by scanning the data matrix code is only possible if the Siemens motor has been provided with a 2D code. 2. With the "Next" button, you synchronize with the cloud. If the motor data set is available in the digital twin database, then you proceed to Step 3/3 - Asset Info.
  • Page 181: Asset Info - Step 3/3

    This applies both to Siemens motors and to motors of other manufacturers. To create a new motor data set, proceed the same as for commissioning, described in Section Procedure - Create a new motor data set (Page 53).
  • Page 182 Maintenance 8.6 Replacing a motor (Android) Procedure 1. Enter the asset data. 2. Select the application type. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 183 - Vector control - U/f control If you are not certain when making the selection, or if the converter is not operated in one of the specified control modes, then select U/f. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 184 Maintenance 8.6 Replacing a motor (Android) 5. Exit step 4/4 using the "Next" button. 6. Complete the replacement process using the "Replace" button. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 185 Maintenance 8.6 Replacing a motor (Android) The progress of the replacement process is displayed. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 186 • Value "0": Motor off (OFF), sensor calibrated • Value "1": Motor status not defined, sensor not calibrated • Value "3": Motor on (ON), sensor calibrated No additional measures are required to support calibration. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 187: Replacing A Motor (Ios)

    • You are logged in to the connectivity module via the "SIDRIVE IQ Config" application. • The Wi-Fi connection has been set up. • The SIMOTICS Connect 400 connectivity module is registered with SIDRIVE IQ Fleet. • You have the necessary authorization (see operating instructions, SIDRIVE IQ Fleet, Section Activate MindSphere user account >...
  • Page 188: Mindsphere Login

    The login dialog for MindSphere is displayed after starting the motor replacement wizard. Note The tenant name is used under which the asset is registered. It is not possible to change the tenant. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 189: Replacement Info - Step 1/3

    After you have successfully logged in, you go directly to Step 1/3 of the motor replacement wizard. 8.7.3 Replacement Info - Step 1/3 In Step 1 - Replacement information, enter the reason why the motor is being replaced. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 190: New Motor Data - Step 2/3

    In the following step, use the serial number and manufacturer's article number of the new motor. If you have not replaced the motor, but for instance you have only changed the operating mode, then you can use the data of the "old" motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 191 Scan the "Data Matrix Code" of the motor by tapping the "Scan Data Matrix" button. Note Motor assignment by scanning the data matrix code is only possible if the Siemens motor has been provided with a 2D code. 2. With the "Next" button, you synchronize with the cloud. If the motor data set is available in the digital twin database, then you proceed to Step 3/3 - Asset Info.
  • Page 192: Asset Info - Step 3/3

    This applies both to Siemens motors and to motors of other manufacturers. To create a new motor data set, proceed the same as for commissioning, described in Section Procedure - Create a new motor data set (Page 89).
  • Page 193 2. Select the application type. 3. Select the operating point. If there are multiple parameter sets in the rating data, select the parameter set that matches the connection conditions of your motor. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 194 - Vector control - U/f control If you are not certain when making the selection, or if the converter is not operated in one of the specified control modes, then select U/f. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 195 Maintenance 8.7 Replacing a motor (iOS) 5. Exit step 3/3 using the "Finish" button. 6. Complete the replacement process using button "Replace Motor". SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 196 IQ Fleet, which means that you can see the actual connection status shortly after commissioning. The connectivity module automatically starts the calibration procedure on the motor. It requires 10 measuring cycles with the motor in the "ON" state and 10 measuring cycles with SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 197 • Value "0": Motor off (OFF), sensor calibrated • Value "1": Motor status not defined, sensor not calibrated • Value "3": Motor on (ON), sensor calibrated No additional measures are required to support calibration. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 198: Replace The Battery

    • Do not heat up the battery above 100 °C. • Protect the battery from direct sunlight, moisture and condensation. Data loss when the battery is changed When a battery is changed, device configuration data are kept in the retentive memory. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 199 8. Put the front cover back in position. Ensure that the cover fits precisely. 9. Tighten the 2 central fastening screws on the front cover. 10.In the "SIDRIVE IQ Config" application, use the "Battery replacement" function to reset the battery status display to 100 %. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 200: Changing The Attachment Position Of The Mounting Bracket

    If the mounting position used for mounting in the factory is unsuitable because of the available space, you can mount the connectivity module on the opposite side of the motor (see Chapter Mounting the mounting bracket (Page 32)). SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 201: Disposal

    • When disposing of the product or waste that occurs in the individual lifecycle phases, carefully comply with country-specific legislation. • Please contact your local authorities for more information about disposal. SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 202: Disposing Of The Connectivity Module

    5. Dispose of the connectivity module in compliance with the applicable national regulations or recycle it. Comply with the directive of the European Parliament and Counsel regarding old electrical and electronic devices (http://eur-lex.europa.eu/legal-content/EN/TXT/? uri=CELEX:32012L0019). SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 203: Disposing Of The Battery

    • Dispose of used lithium batteries individually as special waste. • Dispose of used lithium batteries in compliance with all of the local regulations. • Used lithium batteries can be recycled. Recycle your old batteries! SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 204 Disposal 9.2 Disposing of the battery SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 205: Further Information

    (https://www.youtube.com/watch? v=RShjaqjapxo) Using open-source software (OSS) Open-source software is used in the product SIMOTICS CONNECT 400 either unchanged or modified by us. License conditions and open-source software used that have to be published are stored on the CD-ROM supplied with SIMOTICS CONNECT 400.
  • Page 206: Product Support

    If you have any technical questions or require additional information, please contact Technical Support (https://support.industry.siemens.com/cs/ww/en/sc/4868). Have the following connectivity module data ready: • SIMOTICS CONNECT 400 firmware version • SIDRIVE IQ Config app version • Tenant name • Asset name (onboarded) •...
  • Page 207 A list of available spare parts is available through the spare parts service "Spares on Web (https:// www.sow.siemens.com/)" by selecting the serial number and the MLFB of the motor. In SIDRIVE IQ Fleet in the "Fleet" application area, you will find the link to "Spares On Web" for each configured asset.
  • Page 208: Technical Data

    SIMOTICS CONNECT 400 with integrated sensors monitors the condition of the motor to provide information about motor operation and to enable optimization of the application and process. SIMOTICS CONNECT 400 can only be used in combination with the "SIDRIVE IQ Fleet" MindSphere application. Monitoring application...
  • Page 209 Android version through the Google Play Store, iOS version through the Apple App‐ Store Mechanics / material Material of the housing Industrial plastic Durethan® (polyamide, halogen-free, glass-fiber reinforced), ma‐ terial of the cover seal made of silicone Material of the mounting bracket Stainless steel  SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 210 Weight of the connectivity module, ap‐ 0.25 kg prox. Weight of the Connectivity Kit, including 0.50 kg mounting accessories, approx. Documentation and information Further technical product information and documentation is available at: www.siemens.com/digital-motor (www.siemens.com/digital-motor) SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 211: Directives And Standards

    Frauenauracher Str. 80 91056 Erlangen, Germany SIMOTICS CONNECT 400 complies with the Radio Equipment Regulations UK SI 2017 No. 1206. This equipment must be installed and operated at a minimum distance of 20 cm between the device and users or bystanders.
  • Page 212 (2) This device must accept any interference received, including interference that may cause un‐ desired operation. Any changes or modifications made to this equipment that are not expressly approved by SIEMENS could void the FCC authority to operate this device.
  • Page 213 เครื ่ อ งโทรคมนาคมและอุ ป กรณ์ น มี ้ ◌ ี ค วามสอดคล ้องตามมาตรฐานหรื อ ข ้อกํ า หนดทางเทคนิ ค ของ กสทช. Australia and New Zealand (RCM, formerly C-Tick) SIMOTICS CONNECT 400 meets the requirements for RCM, Australia and New Zealand SIMOTICS CONNECT 400 meets the requirements for IMDA, Singapore.
  • Page 214 Further information 10.4 Directives and standards KVALITET SIMOTICS CONNECT 400 meets the requirements for KVALITET, Serbia Certification number: P1620134400 SIMOTICS CONNECT 400 meets the requirements of MOC, Israel Certification number: 51-78539 SIMOTICS CONNECT 400 meets the requirements of ICT, Vietman Certification number: C0052180121AE01A3...
  • Page 215: Index

    Assigning the motor, (Android), (iOS) iOS, 174, 185 Disclaimer of liability, 9 Disposal, 200 On-site service, 204 Overview, 24 EMC Directive, 209 Establishing a connection Android, 38 iOS, 74 Password Changing, (Android), (iOS) Reset, (Android), (iOS) Performing offboarding, (Android) Generic Vibration monitoring Dashboard, 109, 129 SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...
  • Page 216 Spare parts, 205 Spares on Web, 205 Spares on Web, 205 Starting offboarding, (Android) iOS, 121 Storage conditions, 28 Synchronization intervals, 124 Android, 49, 115, 146 iOS, 86, 163 Technical Support, 204 Transport conditions, 28 Updating SIDRIVE IQ Config Android, 130 iOS, 133 Updating the firmware Android, 130 Visual inspection, 27 SIMOTICS CONNECT 400 Operating Instructions, 04/2023, A5E50161952B AL...

Table of Contents