LAN Connection Check

1. For Token-Ring using shielded twisted-pair cable (Models
001, 011, 201, or 301): Disconnect the LAN cable from the
network, leaving it connected to the adapter.
For Ethernet 10BASE2 (Models 003, 013, 202, or 302): Make
sure the switch is set to position 2 for Models 003 and 013, or
position 16/2 for Models 202 and 302. Attach a 50 ohm BNC
terminator cap to each end of the T-connector. (The customer
may be able to supply these caps.)
For Token-Ring using unshielded twisted-pair cable (Models
201 or 301) or Ethernet 10BASE-T (Models 002, 012, 202, or
302): There is no LAN connection test for these configurations.
Refer to "Printer and LAN Checks".
2. Press the Reset button.
Models 0XX: The status LED will blink several times within 3-4
seconds, turn off for up to 30 seconds, then turn on solid.
Models 20X and 30X: The adapter will go through a reset cycle
and stop with the Power and Status LEDs on.
Any other result indicates a failure of the test. For Token-Ring using
shielded twisted-pair cable, verify the continuity of the cable and replace
the adapter if the cable is good. For Ethernet 10BASE2, replace the
adapter.

Printer and LAN checks

Reset Cycle
Test
Power
1
on
2
on
3
on
4
on
5
on
6
on
End
on
3-6
Laser Printer Reference Handbook
Status
off
on
off
off
off
off
on
Test
Data
off
off
on
on
on
on
on
off
off
on
off
off
off