Operation Verification

This section provides a method to verify that the machine is operating correctly and can be
returned to service. Do these operation verification tests at the end of a maintenance pro-
cedure or whenever it is necessary to ensure that the machine is operating properly.

Operation Verification Tests

Error Code Verification Test
Verify that there are no current active logged error codes:
1. Access either the Error Log (or
logged error codes:
On P10, P30, P30i and P31 LED consoles, Press & hold down the
l
PAUSE/RESET key for 6 seconds minimum to access the Error Log.
On P62, P80, and P82 touchscreen consoles, access Service menu
l
(51765761), select About > CPA Even Log.
2. Resolve any current active logged error code issues.
3. Delete resolved error codes:
On P10, P30, P30i and P31 LED consoles, clear the Error Log, see
l
Log & CPA Event Log" on page
Press and hold the PAUSE/RESET key for 6 seconds minimum to access
the Error Log. If there are no logged error codes, the "Stuck Key" message
will show. To remove an error code, press/hold down the QUICK START
key until the "NO ERRORS" message shows.
. On P62, P80, and P82 touchscreen consoles, error codes cannot be
l
deleted from the CPA Event Log)
Console Verification Tests
Verify the LED console or touchscreen console operation.
LED consoles (P10, P30, P30i and P31) only
1. Access the Diagnostic/Test menu (51765761) and run the following tests:
KEYPAD TEST: Select KEYPAD TEST and follow prompts to run test.
l
DISPLAY TEST: Select DISPLAY TEST and follow prompts to run test.
l
2. Exit the Diagnostic Test menu (press the PAUSE/RESET key).
Touchscreen consoles (P62, P80, and P82) only
1. Access the Service menu (51765761) and perform the following console System
Tests (Settings > System Settings > System Tests):
1
Touchscreen console Control Processing Assembly.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
CPA
Event Log) and record any current active
95.