Table 38
Output Fields for the show disk Command
Field
Capacity
Mounted on
(1) The size of the root file system includes the sizes of the /flash file system and the p0 and p1 partitions on the
internal-storage device.
(2) The size of the /md file system does not include the partition for SmartEdge OS core dumps on the external storage
device; the partition for core dumps is approximately 500 MB.
(3) The number of usable 512-byte blocks (the sum of the Used and Avail fields) on a storage device is approximately
95% of the number of 512-byte blocks.
(4) The capacity of an external storage device can decrease slightly over time if sectors are marked as unusable
(cannot be read or written).
3.7

Output Fields for the show hardware Command

This command displays information only for those units that are installed in
the chassis.
Table 39
Output Fields for the show hardware Command
Field
Fan(s) Status
Power Supply A1 Status
Power Supply A2 Status
Power Supply B1 Status
Power Supply B2 Status
Active Alarms
Slot
Type
Mfg Date
56
Description
Percentage of blocks used in the file system, calculated using the number of usable blocks (Used +
(3) (4)
Avail)
Device on which the file system is mounted:
• /—Internal compact-flash card
• /md—Mass-storage device in the external slot
Description
• Failed—At least one fan is not working.
• Normal—All fans are working.
• No Power—Power has failed, is disconnected, or is not installed.
• Normal—Power is being supplied by this power supply.
Alarm conditions for this unit:
• NONE—No alarm conditions exist.
• condition—Alarm condition is in effect.
For a complete list of conditions that can cause an alarm, see the Troubleshoot with System
Power and Alarm LEDs section.
• slot—Slot number for this unit.
• N/A—No slot number for this unit.
Unit:
• backplane—Backplane.
• traffic-card-type—Line card is configured.
• fan tray—Fan tray is installed.
• unknown—Card is inserted but not initialized.
dd/mm/yyyy—Date unit was manufactured.