Siemens SIMATIC Ident Function Manual page 85

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Byte
Value
Byte 16
field_on_
time
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
RFID system Meaning
6
ScanningMode (relevant for multitag mode):
7
Reserved
RF200
Transponder type
0x01
Any ISO transponder
RF300
Selection of the transponder types used
With the value "0x01"/"0x31" (ISO 15693 general), the readers of the 2nd genera-
tion always use the ISO commands with which the highest performance can be
achieved for the particular transponder. With readers of the 1st generation, the
value "0x01" activates the general ISO mode with rudimentary ISO commands.
With this setting, the performance is generally limited, but the operation is basically
guaranteed with each ISO-compatible transponder.
The transponder chip types of the transponders specified in the system manual
"SIMATIC RF300" in the section "RF300 transponders" support these commands.
The following values can be set:
Value
Transponder
type
0x00
RF300
(RF3xxT)
0x01
ISO 15693
general
0x03
ISO 15693
(Infineon, MDS
D3xx)
0x04
ISO 15693
(Fujitsu - 2 kB,
MDS D4xx)
0x05
ISO 15693
(NXP, MDS
D1xx)
0x06
ISO 15693
(TI, MDS D2xx)
0x07
ISO 15693
(STM, MDS
D261)
0x08
ISO 15693
1)
(Fujitsu - 8 kB,
MDS D5xx)
0x10
RF300
1)
(RF3xxT)
0x00 = Normal multitag mode without ScanningMode (including "re-
peat_command")
0x01 = ScanningMode
Unspecified read commands (UID = 0x00) are also accepted by the
CM/reader if there is more than one transponder in the antenna field.
By setting bit 6 to 0x01, the reader in multitag mode is prepared for
the use of "ScanningMode".
Description
For all transponders of the type "RF3xxT"
Any ISO transponder
Activation of the general ISO mode with rudimentary
ISO commands. With this setting, operation is basically
guaranteed with every ISO-compatible transponder.
e.g. MDS D324, D339
e.g. MDS D421, D422, D423, D424, D425, D426,
D428, D460
e.g. MDS D100, D124, D126, D139, D150, D165
e.g. MDS D200
e.g. MDS D261
e.g. MDS D521, D522, D524, D525, D528
For all transponders of the type "RF3xxT"
Configuring the instructions
4.6 Programming the Ident profile
85

Advertisement

Table of Contents
loading

Table of Contents