Parameter
UID_HANDLE
BLACK_LIST
TAG_HOLD
PARAM_SET
CHANNEL_PLAN
MULTITAG
ISTM
SCANNING_MOD
E
Is not currently possible with the Ident blocks.
1)
4.5.5.6

Reset_Univ

The "Reset_Univ" instruction is a universal reset statement that can be used to reset
identification systems. Use this instruction only in consultation with Support.
Figure 4-27
Table 4- 41
Parameter
PARAM
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
Data type
BOOL
BOOL
BOOL
SINT
SINT
SINT
BOOL
BOOL
Instruction "RESET_Univ"
Explanation for the instruction "RESET_Univ"
Data type
SINT [16]
4.5 Programming add-on instructions
Default values
Description
False
Meaning of the UID in the command:
True = Handle ID, only the least signif-
icant 4 bytes of the UID are evaluated;
False = UID/EPC-ID with a length of 8
bytes
False
True = Activate Black List
False
True = Activate Tag Hold
0x00
Field_ON_Control
(0 = fast; value range: 0x00, 0x02)
0x0F
Field_ON_Time
(value range: 0x00 ... 0x0F; ETSI only)
0x01
Maximum number of transponders
that can be processed at the same
time in the antenna field.
(Range of values: 0x01 ... 0x50)
False
True = activate intelligent single tag
mode
False
True = Activate Scanning Mode
Default values
Description
Data for reset frame
The data to be set here can be made
available by Support when necessary
for special settings.
Configuring the instructions