Error messages

5.2 Errors from the communications module/reader

5.2
Errors from the communications module/reader
The causes of these errors can, for example, be as follows:
● Errors have occurred in communication between the CM and the reader or between the
reader and the transponder.
● The communications module is unable to process the command.
Byte 3 of the "STATUS" is not relevant for the error messages.
Table 5- 2
Error messages from communications module/reader or from the Ident profile via the STATUS output parame-
ter
Error mes-
Description
sage
(hex)
0xE1FE01
Memory of the transponder cannot be written to
Transponder memory is defective
Transponder EEPROM was written too frequently and has reached the end of its service life
RF620R/RF630R: Transponder is write protected (Memory Lock)
0xE1FE02
Presence error: The transponder has moved out of the transmission window of the reader. The command
was executed only partially.
Read command: "IDENT_DATA" has no valid data.
Write command: The transponder that has just left the antenna field contains an incomplete data record.
Operating distance from reader to transponder is not being maintained
Configuration error: The data record to be processed is too large (in dynamic mode)
With timeout: No transponder in the antenna field
0xE1FE03
Address error
The address area of the transponder has been exceeded.
Start address of the command start has been incorrectly set
Transponder is not the correct type
Attempted write access to write-protected areas
0xE1FE04
Only during initialization: Transponder is unable to execute the initialization command
Transponder is defective
0xE1FE06
Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery failure.
Replace transponder (if battery bit is set)
Re-initialize transponder
0xE1FE07
Password error
RF620R/RF630R: Incorrect password
0xE1FE08
The transponder in the antenna field does not have the expected UID or has no UID.
0xE1FE0A
The transponder is read/write-protected.
0xE1FE81
The transponder is not responding.
0xE1FE82
The transponder password is incorrect. Access is denied.
0xE1FE83
The verification of the written transponder data has failed.