Write_EPC_Mem

The "Write_EPC_Mem" instruction overwrites the EPC memory of the RF600 transponder
starting at address 4. The length of the EPC memory to be overwritten is specified by the
"LEN_DATA" parameter.
Figure 4-18
Table 4- 22
Parameter
LEN_DATA
LEN_ID
EPCID_UID
IDENT_DATA
42
Instruction "Write_EPC_Mem"
Explanation for the instruction "Write_EPC_Mem"
Data type
INT
SINT
SINT[62]
SINT[10]
Default values
Description
0x00
Length of the EPC memory to be
overwritten (1 ... 62 bytes)
0x00
Length of the EPC-ID/UID
Default value: 0x00 ≙ unspecified
single tag access (RF68xR)
0
Buffer for up to 62 bytes EPC-ID, 8
bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at
the start of the buffer (length is set
by "LEN_ID")
8-byte UID is entered at the start
of the buffer ("LEN_ID = 8")
4-byte handle ID must be entered
in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified
single tag access (RF620R, RF630R)
0
Data buffer with the EPC memory data
to be overwritten.
Note:
When necessary, an array of any size
can be transferred to this parameter.
Note that the array must be ≥ 10 bytes
long (e.g. "SINT[12400]").