Layer 2 QoS
802.1Q/VLAN Tag
Layer 2 QoS 802.1p
Priority Value
PC Port Mode
PC Port VLAN Tag
PC Port Priority Value
Enable CDP
Enable LLDP
LLDP TX Interval
Maximum
Transmission Unit
(MTU)
Network → Remote Control
Action URI Support
Remote control Pop
up window support
Action URI allowed IP
list
CSTA Control
Network → Affinity Settings
Affinity Support
Preferred Account
Network → Bluetooth Settings
Bluetooth Power
VLAN to configure VLAN tag and priority. Default is "Enabled".
Assigns the VLAN Tag of the Layer 2 QoS packets. The default value is 0.
Assigns the priority value of the Layer2 QoS packets. The default value is 0.
Configure the PC port mode. When set to "Mirrored", the traffic in the LAN
port will go through PC port as well and packets can be captured by
connecting a PC to the PC port. The default setting is "Enabled".
Assigns the VLAN Tag of the PC port. The default value is "0".
Assigns the priority value of the PC port. The default value is "0".
Enables/Disables CDP "Cisco Discovery Protocol".
Controls the LLDP (Link Layer Discovery Protocol) service. The default
setting is "Enabled".
Defines LLDP TX Interval (in seconds). Valid range is 1 to 3600.
Defines the MTU in bytes. Default is 1500 bytes.
Enable/disabled action URI feature on the phone.
Indicates whether the phone is enabled to pop up allow remote control.
List of allowed IP address from which the phone receives action URI. The
Allowed
IP
addresses
"192.168.1.1,192.168.1.2". Set this field to "any" to allow any IP address to
send Action URL to the phone. The default value is empty string which
means no IP address is allowed for remotely control the phone.
Indicates whether CSTA Control feature is enabled. Change of this
configuration will need the system to reboot to take effect.
Allows communication with GS Affinity CTI application to manage telephone
calls from computer. If enabled, a reboot is required to establish the
communication. Default is "Disabled".
GS Affinity CTI Application is available
Selects the account on which CTI support is enabled.
Configures Bluetooth to power on, off or off with hiding menu from LCD.
Default setting is "On".