To configure MEG level of MEP.
Example:
To configure MEG level (2) of MEP 2.
Switch# configure terminal
Switch (config)# mep 2 level 2
4.2.137 mep <Instance> lm
Command:
mep <Instance> lm <prio> [ multi | uni ] [ single | dual ] [ fr10s | fr1s | fr6m | fr1m |
fr6h ] [ flr <flr> ]
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
lm
Loss Measurement
<Prio : 0-7>
Priority in case of tagged OAM. In the EVC domain this is the COS-ID.
fr10s
Frame rate is 10 f/s.
fr1m
Frame rate is 1 f/min.
fr1s
Frame rate is 1 f/s.
fr6h
Frame rate is 6 f/hour.
fr6m
Frame rate is 6 f/min.
dual
Dual ended LM is based on CCM PDU.
single
Single ended LM is based on LMM/LMR PDU.
multi
OAM PDU is transmitted with multicast MAC.
uni
OAM PDU is transmitted with unicast MAC. The MAC is taken from peer MEP MAC database. In case of LM
there is only one peer MEP.
flr
The Frame Loss Ratio interval.
<Flr : uint>
The Frame Loss Ratio interval value.
Default:
Usage Guide:
To configure Loss Measurement of MEP.
Example:
To configure Loss Measurement of MEP 2 as below table