Should I allow the battery to discharge completely before charging?
No. It is better to recharge the battery often and avoid frequent full discharge.
However, allow a full discharge once a month to enable reset.
Should I charge the battery partially or fully?
Once calibration has been done, it does not matter whether you charge the
battery fully or partially. Charging a full battery will not harm the battery.
Should I charge the battery before putting it into storage?
It is advisable to store the battery with a 40% charge. However, storing the battery
in a cool place is more important than the state of charge. In addition, make sure
that the battery is not fully depleted before putting it in storage. Otherwise, the
safety/protection circuit may trip.
Will the battery heat up during charging?
It is normal for the battery to emit a small amount of heat during charging. The
Smart battery is equipped with a temperature sensor that will disrupt the flow of
charge current when extreme temperature levels are detected.
The recommended operating temperature for the VX 680 is from 0
°
°
(32
F to 122
F).
How often must I perform battery conditioning?
It is recommended to perform battery conditioning once every three months or
each time 80 short charge/discharge cycles have been completed.
Many batteries undergo periodic full discharges as part of their regular use. In
cases like this, no additional calibration is needed.
If no discharge reset has occurred for a few months, the battery pack must fully
discharged manually.
The following terms and definitions apply to the VX 680 terminal's battery.
Calibration
This refers to the process of determining a battery pack's full capacity. It is based
on the completion of the initialization or conditioning process and is required when
the VX 680 terminals screen displays the message BATTERY NOT
CALIBRATED.
VX 680 S
B
I
MART
ATTERY

Smart Battery FAQs (for VX 680)

°
C to 50
VX 680 R
EFERENCE
NFORMATION
°
C
175
G
UIDE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents