Manual
Digital display
y
x
w
Adjustment/
Adjustment/
display area
dPI
--.--- to ----
dAI
-- 1,999 to 19,999
dEI
-- 1,999 to 19,999
dPII
--.--- to ----
dAII
-1,999 to 19,999
dEII
-1,999 to 19,999
A1
--110 to +110 %
A2
referenced to
A3
dE -- dA
A4
see table 3-4
H1.2
0.1 to 20.0
H3.4
0.1 to 20.0
SA
--10 to +110 %
SE
referenced to
SH
dE -- dA
Sb
see table 3-6
tS
oFF, 0.1 to 9984
vA
0.000 to 9.999
vE
0.000 to 9.999
yS
--10.0 to 110.0
y1
0.0 to 100.0
y2
0.0 to 100.0
--1.1
0.1
1.1
--10 to 110 %
referenced to
11.1
dE -- dA
--1.3
or
0.3
--199.9 to 199.9 %
1.3
see table 3--6,
page 184
11.3
--10
FU1
--199.9 to 199.9
0
FU1
--199.9 to 199.9
10
FU1
--199.9 to 199.9
110
FU1
--199.9 to 199.9
--10
FU2
--199.9 to 199.9
0
FU2
--199.9 to 199.9
10
FU2
--199.9 to 199.9
110
FU2
--199.9 to 199.9
PA
rE
0.010 to 1.000
PE
rE
1.000 to 99.99
tA
rE
0.010 to 1.000
TE
rE
1.000 to 99.99
SAII
--10 to 110 %
SEII
referenced to
dEII -- dAII
tSII
oFF, 0.1 to 9984
YSII
--10.0 to 110.0
Pd
--.--- to ----
Ad
-- 1999 to 19999
Ed
-- 1999 to 19999
H2
0.1 to 20.0
H4
0.1 to 20.0
y3
0.0 to 100.0
y4
0.0 to 100.0
Table 3-5
Parameter list oFPA
SIPART DR22 6DR2210
C79000-G7476-C154-03
3.3
Configuring level (parameterization and structuring mode)
Fac-
Resolution
Di-
tory
tory
men-
men-
setting
sion
----.-
--
--
000.0
1 digit
--
100.0
1 digit
--
----.-
--
--
000.0
1 digit
--
100.0
1 digit
--
5.0
1 digit
--
--5.0
or
--
5.0
0.1 %
--
--5.0
--
1
0.1
%
1
0.1
%
--5.0
1 digit
--
105.0
or
--
0.0
0.1 %
--
0.0
--
oFF
min
0.000
0.001
1
1.000
0.001
1
0.0
0.1
%
50.0
0.1
%
50.0
0.1
%
--10.0
--
0.0
--
10.0
1 digit
--
--
110.0
or
--
--10.0
--
0.0
0.1 %
--
10.0
--
--
110.0
--
--10
0.1
%
0
0.1
%
10
0.1
%
110
0.1
%
--10
0.1
%
0
0.1
%
10
0.1
%
110
0.1
%
1
0.001
1
1
0.001/0.01
1
1
0.001
1
1
0.001/0.01
1
--5.0
1 digit
--
105.0
or
--
0.1 %
oFF
min
0.0
0.1
%
----.-
--
--
000.0
1 digit
--
100.0
1 digit
--
1
0.1
%
1
0.1
%
50.0
0.1
%
50.0
0.1
%
3.3.4
Structuring mode oFPA (offline Parameters)
Parameter meaning
Decimal point display I
}
Start value
Display range
Full scale value
Display I
Decimal point display II
Start value
Display range
}
Full scale value
Display II
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Hysteresis alarms A1 and A2
Hysteresis alarms A3 and A4
Setpoint limit start
Setpoint limit end
Safety setpoint
Limit setpoint for override control
Setpoint ramp
Ratio factor start
Ratio factor end
Safety manipulated variable
Manipulated variable range y1
Manipulated variable range y2
Linearized FE1 vertex value at --10 %
Linearized FE1 vertex value at 0 %
Linearized FE1 vertex value at --10 %
Linearized FE1 vertex value at 110 %
Linearized FE3 vertex value at --10 %
Linearized FE3 vertex value at 0 %
Linearized FE3 vertex value at 10 %
Linearized FE3 vertex value at 110 %
Function transmitter 1 vertex value at --10 %
Function transmitter 1 vertex value at 0 %
Function transmitter 1 vertex value at 10 %
Function transmitter 1 vertex value at 110 %
Function transmitter 2 vertex value at --10 %
Function transmitter 2 vertex value at 0 %
Function transmitter 2 vertex value at 10 %
Function transmitter 2 vertex value at 110 %
Correction quotient pressure start
Correction quotient pressure end
Correction quotient temperature start
Correction quotient temperature end
}
Setpoint limit start
Controller II
Setpoint limit end
when S1 = 12
Setpoint ramp
Controller II when S1=12
Safety manipulated variable Controller II when S1=12
display range
ratio controller
Hysteresis alarms A2 at S267 ≠ 1
Hysteresis alarms A4 at S268 ≠ 1
Manipulated variable range y3
Manipulated variable range y4
3 Operation
}
at
Split range
only when
S4= 0
and
S20 or
S21≠1
only when
S4= 1
and
FU1 or
FU2=YE
S
only when
S4=1
Split range controller II
}
at S1 = 12
183