located on this PC.
Manual retrieval of data from the device: Any data available on the device are displayed, however, a portion of
them has been retrieved some days ago. (For data redundancy reasons, the data transferred are not
immediately deleted.)
Transfer of measured data from a different computer: Data from a certain measurement location are retrieved
from on location by a laptop. On the laptop, the data path is released for storage so that these new data can be
imported from the server. For this purpose, no manual selection of the intervals is necessary any longer.
Once the data has been successfully transferred, the data in the lower list appear with a checkmark.
Show unsent messages
Depending on how it is parameterized, the device can send messages in response to various events. If sending a
message is not possible, a notification about it is left in the device, and additionally the message text contains the
information about the number of messages successfully sent and of those not successfully sent.
Using the button Show unsent messages, the device information is sent to the PC and displayed in an Explorer
window. The sending notification is deleted from the device.
- The filename contains the time when the notification is to be sent.
- The file contents is the message text.
SICAM Q80 7KG8080 data are stored on the device's hard drive in a special format. Only upon being transferred, the
data are converted to a format which can be read.
Note
Measured data on the hard drive which originate from SICAM Q80 7KG8080 can only
be processed by SICAM Q80 Manager software!
If your PC is equipped with a Compact Flashcard drive, the hard drive can be removed from
the SICAM Q80 7KG8080 unit and inserted into the PC, and the data to be transferred are
selected using the button Search PC.
Only SICAM Q80 7KG8080 data contain extra information such as the measurement location
and the actual measurement time.
Information on this page have nothing more to do with the measurement configuration and
isn't saved; only the device selection remains.
With brief measurements it is possible that certain measured quantities can not be
determined. In this case, a message appears indicating that no data are available.
From the above list of measurement intervals found, all data are imported, which are still
Section of Microsoft Explorer showing unsent messages