COMMUNICATION Menu (emulation)
Setup
Possible
Parameters
Values
Meanings
Transmit
See page
The display station sends data to the host system at the
3-23
selected line speed (bps).
Receive
TRANSMIT
The transmit line speed (bps) is used for the display station
to receive data from the host system.
Data Length
817
The display station uses the selected data length (7-bit or
8-bit).
Parity
NO
The display station uses the selected parity. Parity is not
EVEN
added when NO is selected.
ODD
MARK
SPACE
Parity Check
ON
I
OFF
When ON is selected, parity is checked.
Stop Bit
112
The display station places one or two bits after each data
character.
XOFF
64
The display station sends an XOFF character to the host
128
system when the buffer of the display station is filled with
300
the selected number of characters, or no XOFF character
NO
is sent (when NO is selected).
Interface
RS-232C
The display station communicates with the host system
RS-422A
using the EIA RS-232C or RS-422A interface.
Figure 3-6 (Part 1 of 2). Setup Parameters in the COMMUNICATION Menu (emulation)