NORMAL SHUTDOWN
1. Turn off the lamps by pressing the lamp switch on the
control panel.
2. Let the engine idle for a few minutes with no load.
3. Turn the ignition key to the off position. Store the key
in a safe location.
EMERGENCY SHUTDOWN
4. Place the key switch in the STOP position. Remove
key. Place fuel lever in the OFF position.
LOWERING THE MAST AND LAMPSTAND AFTER
USE
1. Turn the winch handle counterclockwise and observe
the mast until it is completely lowered. The mast locking
shackle will lock automatically.
2. To lower lampstand, turn down and hold the actuator
switch to the storage position.
PAGE 28 —GBX24S/GBX24B LIGHT TOWER • OPERATION AND PARTS MANUAL — REV. #0 (05/30/19)
OPERATION