Control Panel - MULTIQUIP GLOBUG GBX24S Operation Manual

Light tower
Table of Contents

Advertisement

10
1. Fuses — Provide circuit protection.
a. Fuse 1 (5 A) - protects the starter circuit
b. Fuse 2 (5 A) - protects the circuit of preheating
engine
c. Fuse 3 (10 A) - protects the ECU
d. Fuse 4 (20 A) - protects the motor winch case
e. Fuse 5 (20 A) - protects the engine key switch and
component wiring
Fuse 6 (30 A) - protects the circuit of the engine
f.
heater
2. Glow Lamp — Lights to indicate engine error.
3. Ignition Key Switch — Starts the engine.
4. Actuator Switch — When turned, raises or lowers
the lampstand.
GBX24S/GBX24B LIGHT TOWER • OPERATION AND PARTS MANUAL — REV. #0 (05/30/19) — PAGE 19
9
8
7
6
5
Figure 5. GBX24S/GBX24B Control Panel

CONTROL PANEL

5. Lamp Breaker — 25A circuit breaker protects lamps
from overload. When there is an overload, breaker trips.
When problem is corrected, press the breaker to reset.
6. Lamp Switch — When pressed, turns all the lamps
on or off.
7. Dimming Control Switch — When pressed, changes
the brightness of the lamp from 100% down to 40%.
8. Dimming Meter — Indicates the percentage of the
lamps' brightness.
9. Hour Meter — Indicates the number of hours that the
machine has been in use.
10. Panel Lamp — Lights the panel.