IBM e Server i Series Manual page 32

Disk unit, disk expansion unit, disk unit enclosure.
Hide thumbs Also See for e Server i Series:
Table of Contents

Advertisement

__ 27. When the above conditions are met, press F12 twice to return to the Work
__ 28. On the Include Disk Units in Device Parity Protection display, select the disk
__ 29. Press Enter to confirm your choice. The configuration will start and may
__ 30. When the device parity protection is complete, the message "Selected units
__ 31. Select Display disk configuration on the Work with disk configuration
__ 32. Select Display disk configuration status on the Display disk configuration
__ 33. If you have more than one ASP, determine the auxiliary storage pool (ASP)
__ 34. Press F12, twice.
__ 35. Select Work with ASP configuration on the Work with disk configuration
__ 36. Select Add units to ASPs on the Work with ASP configuration display.
__ 37. Specify the ASP you determined in step 33 on the Specify ASPs to Add Units
__ 38. Press Enter to confirm.
__ 39. When the message "Selected units have been added successfully" appears,
__ 40. Go to step 45 on page 27.
__ 41. Select Work with ASP configuration on the Work with Disk Configuration
__ 42. Select Add units to ASPs on the Work with ASP configuration display.
__ 43. Specify the number of the ASP to which you want to add the disk unit.
26
43xx Disk Unit, 71xx Disk Expansion Unit, 71xx Disk Unit Enclosure V5R3
not for the Include Device Parity Protection operation. For more
information, refer to Backup and Recovery
v All disk units in a parity set must be the same capacity with a
minimum number of three or four disk units and maximum of 10 or
18 units in the resulting parity set, depending on the disk unit type.
v Not all disk units attached to an advanced function input/output
processor have reported to the system. Retry the operation.
v The type/model of the disk units is not supported for the requested
operation.
with Disk Configuration display.
units to be included in Device Parity Protection. Type a 1 in the Option
column.
Press Enter.
take 30 to 60 minutes to complete.
have been included successfully" appears on the Work with device parity
protection display.
Press F12.
display.
Press Enter.
display.
to which you want to add the disk unit.
display.
Press Enter.
Press Enter.
to display.
Press Enter.
press F3 three times and press Enter to return to the Main Menu.
display and press Enter.
Press Enter.
The system ASP is ASP 1.
Press Enter.
.