Expanding and assigning parameters to the device
6.1
Retrofitting instructions
Temperature range 5 °C to 35 °C
The maximum permissible power loss of the expansion cards amounts to 75 W.
Distribution to the slots without exceeding the total power:
● 25 W for the expansion cards in Slot 1, 2, 3, 4 maximum
Maximum permitted configuration
Note
During operation, the HDDs installed in the removable drive bay must not be exposed to
vibratory loads and may only be exposed to limited shock loads (see Technical
specifications).
Temperature range 5 °C to 40 °C
The maximum permissible power loss of the expansion cards amounts to 55 W.
Distribution to the slots without exceeding the total power:
● 25 W for Slot 1 maximum
● 25 W each for Slot 2, 3 maximum
● 15 W for Slot 4 maximum
Maximum permitted configuration
SIMATIC IPC647D
Operating Instructions, 01/2014, A5E32996306-AA
6
59