8.4

Technical specifications

8.4.1

General specifications

General specifications
Order number
Dimensions
Weight
Supply voltage (V
Input current AC
Line voltage frequency
Transient voltage interruption
Power consumption
Power loss / heat emission
Current delivery (DC)
Noise emission
Degree of protection
Dust protection
Safety
Protection class
Safety regulations
SIMATIC IPC647D
Operating Instructions, 01/2014, A5E32996306-AA
6AG4112-2...(for details, refer to the ordering documentation)
430 × 88.1 × 444.6 (W × H × D in mm). Detailed dimensional
specifications can be found in section Dimensional drawing of
the device (Page 121).
Min. 10 kg, max. 14 kg
)
100 to 240 VAC (–15%, 10%), varying voltage; with transient
N
power failure backup in accordance with NAMUR
Continuous current up to 6 A (up to 30 A for 5 ms at startup)
50 to 60 Hz (min. 47 Hz to max. 63 Hz, sinusoidal)
Min. 20 ms at 93 V
(max. 10 events per hour; recovery time at least 1 s)
AC power supply: Max. 240 W at 80% efficiency
Redundant AC power supply: Max. 240 W at 80% efficiency
AC power supply: 240 W = 240 J/s = 0.23 BTU/s
Redundant AC power supply: 240 W = 240 J/s = 0.23 BTU/s
+5 V/30 A + 3.3 V/28 A, max. aggregate power 160 W
+12 V/15 A -12 V/0.5 A -5 V/0.5 A +5 Vaux/2 A
Aggregate power of all voltages max. 190 W
< 45 dB(A) at 25 °C according to DIN EN ISO 7779
ODDs not in operation
IP41 at the front and IP20 at the rear according to IEC 60529
With closed front panel
Filter class G2 EN 779, 99% of particles > 0.5 mm are filtered
Protection class I according to IEC 61140
IEC 60950-1
EN 60950-1
UL 60950-1
CSA C22.2 No 60950-1-07