Technical Specifications; Applicability Of Technical Specifications; General Technical Specifications - Siemens SIMATIC IPC647E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC647E:
Table of Contents

Advertisement

Technical specifications

8.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter pad are installed.
• The device is closed.
• The connected I/O devices meet the requirements for the respective area of application
(interference emission according to EN 61000-6-3 / IEC 61000-6-3, immunity to
interference according to EN 61000-6-2 / IEC 61000-6-2).
8.2

General technical specifications

See the note in "Applicability of technical specifications (Page 153)".
Article number
Dimensions
Weight
Supply voltage (U
; AC)
N
Transient overvoltages
SIMATIC IPC647E
Operating Instructions, 09/2022, A5E52254141-AA
6AG4112-3...-.... (for details, refer to the ordering documentation)
481.4 x 88.1 x 446.6 (W × H × D in mm)
You can find detailed information on the dimensions under "Dimension drawing of the device
(Page 174)".
10 up to 14 kg; depending on the equipment
Single power supply (400 W; AC):
100 V to 240 V AC (-15%; +10%)
Redundant power supply (350 W, AC):
2 × 100 V to 240 V (-15%; +10%)
Device is designed for connection to supply with overvoltage category II
(Transient overvoltages up to 2500 V)
8