Venting - Direct Vent System (Flex) - Regency Bellavista B36XTCE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTCE:
Table of Contents

Advertisement

installation
VENTING
DIRECT VENT SYSTEM (FLEX)
HORIZONTAL TERMINATIONS ONLY
These venting systems, in combination with the B36XTCE Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock
Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Loca-
tions" section.
Regency Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the B36XTCE with a maximum run of 4 feet.
1)
6-7/8" dia. flexible liner (4 ft. length)
2)
4" dia. flexible liner (4 ft. length)
3)
spring spacers (4)
4)
thimble (2)
5)
AstroCap termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
If longer runs are needed, the Regency Direct
Vent system (Flex) # 946-516 includes all the
parts needed to install the B36XTCE with a
maximum 10' run.
1)
6-7/8" dia. flexible liner (10 ft. length)
2)
4" dia. flexible liner (10 ft. length)
3)
spring spacers (7)
4)
thimble (2)
5)
AstroCap termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
Notes:
1. Liner sections should be continuous without any joints or seams.
2. Only Flex pipe purchased from Regency may be used for Flex installations.
|
30
Bellavista® B36XTCE-11 Gas Fireplace
Reducer (946-758)
Must purchase separately
Minimum Height Requirement of
49" (1245mm) from base of unit
when using reducer