[Channel %1: ] Block %2 leading axis/spindle %3 maximum number of CP master
values (%4) exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP master values
Definitions:
An attempt was made to activate more master values of generic couplings than are configured in MD18452
$MN_MM_NUM_CP_MODUL_LEAD.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of defined or active master values, or increase the total number of master values configured in
MD18452 $MN_MM_NUM_CP_MODUL_LEAD.
If necessary, buy another option stage of the generic coupling.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16673
[Channel %1: ] Block %2 leading axis/spindle %3 maximum number of CP master
values (%4) exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP master values
Definitions:
An attempt was made to activate more master values of generic couplings than are configured in MD18452
$MN_MM_NUM_CP_MODUL_LEAD.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Reduce the number of defined or active master values, or increase the total number of master values configured in
MD18452 $MN_MM_NUM_CP_MODUL_LEAD.
If necessary, buy another option stage of the generic coupling.
Program
Clear alarm with the RESET key in all channels. Restart part program.
Continuation:
16675
[Channel %1: ] block %2 following axis/spindle %3 coupling module already defined in
channel %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis/spindle
%4 = Channel number
Definitions:
An attempt was made to define or activate a CP coupling, although a coupling had already been defined or activated
on this following axis/spindle in another channel.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change the part program: A CP coupling module must not be simultaneously defined in multiple channels for the same
following axis/spindle.
Program
Clear alarm with the RESET key. Restart part program