Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Set $AA_ESR_ENABLE[axis] = 0 before axis exchange.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Set $AA_ESR_ENABLE[axis] = 0
26124
[Channel %1: ] Axis %2, $AC_ESR_TRIGGER triggered but axis is NEUTRAL and
cannot execute ESR
Parameters:
%1 = Channel
%2 = Axis, spindle
Definitions:
Channel-specific ESR ($AC_ESR_TRIGGER) triggered, but one axis with ESR configuration is NEUTRAL at the time
of triggering.
Neutral axes are ignored with ESR (apart from single axes which react only to $AA_ESR_TRIGGER[Ax]).
Reaction:
Alarm display.
Remedy:
$AA_ESR_ENABLE[Achse] = 1 should not be set with neutral axes.
Alarm can be suppressed via MD11415 $MN_SUPPRESS_ALARM_MASK_2 bit 6 = 1.
Program
Clear alarm with the Delete key or NC START.
Continuation:
29033
[Channel %1: ] Axis exchange of axis %2 not possible, PLC axis movement not yet
completed
Parameters:
%1 = Channel number
%2 = Axis
Definitions:
A PLC axis has not yet reached its end position and cannot be returned to a channel or neutralized. This alarm should
not occur when PLC data block FC18 is used.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Wait until the axis has reached the end position or terminate the movement with delete distance to go.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61000
%[[Channel %1: ] Block %2: %]No tool offset active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: LONGHOLE, SLOT1, SLOT2, POCKET1 bis POCKET4, CYCLE63, CYCLE64,
CYCLE71, CYCLE72, CYCLE90, CYCLE93 through CYCLE96, CYCLE952.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
D-correction must be programmed before the cycle call.
Program
Clear alarm with the RESET key. Restart part program
Continuation: