Too Many Directories In The Nc Memory; Too Many Subdirectories; Data Format Not Allowed - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
6540

Too many directories in the NC memory

Definitions:
The number of directories in the NC file system (part of the NC memory) has reached the maximum limit.
Reaction:
Alarm display.
Remedy:
- Delete or unload directory (e.g. workpiece), or
- Increase MD18310 $MN_MM_NUM_DIR_IN_FILESYSTEM.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6550

Too many subdirectories

Definitions:
The number of subdirectories in a directory of the NCK has reached the maximum limit.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Delete or empty subdirectories in the respective directory, or
- Increase MD18270 $MN_MM_NUM_SUBDIR_PER_DIR.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6560

Data format not allowed

Definitions:
An attempt was made to write impermissible data in an NCK file. This error can occur in particular when the attempt
was made to load binary data in the NCK as ASCII file.
The error can also occur during preprocessing of cycles (see MD10700 $MN_PREPROCESSING_LEVEL) if the NC
block is very long. In this case, subdivide the NC block.
Reaction:
Alarm display.
Remedy:
Specify that the file concerned is a binary file (e.g. extension: .BIN).
Program
Clear alarm with the Delete key or NC START.
Continuation:
6570
NC memory full
Definitions:
The NC card file system of the NCK is full. The task cannot be executed. Too many system files were created in the
DRAM.
Reaction:
Alarm display.
Remedy:
Start fewer "execute from external" processes.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6580
NC memory full
Definitions:
The NC card file system of the NCK is full. The task cannot be executed. To many files have been loaded
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Clear alarm with the Delete key or NC START.
Continuation:
64
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents