Axis %1 Drive %2 Error When Reading A File (%3, %4); Error When Storing A File (%1, %2); Error When Reading A File (%1, %2) - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

611D drive alarms
300411

Axis %1 drive %2 error when reading a file (%3, %4)

Parameters:
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
Definitions:
An attempt to read a data block, e.g. a drive boot file, from the file system has failed. The data block or the file system
is damaged.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
If the error occurred during power-up, i.e. it is probably connected to a drive boot file, delete all boot files and load them
back into the control from the back-up copy.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
300412

Error when storing a file (%1, %2)

Parameters:
%1 = Error code 1
%2 = Error code 2
Definitions:
An attempt to save a data block, e.g. the result of a measuring function, in the file system has failed.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Create more space in the file system. It is normally suffi-
cient to delete 2 NC programs or to free 4 - 8 Kbytes of memory. If these remedies do not work, it will be necessary to
increase the number of files per directory or the size of the file system itself. To do so, proceed as follows:
- Save all data
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR
- 18310 $MM_NUM_DIR_IN_FILESYSTEM
- Power On
- Reload saved data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
300413

Error when reading a file (%1, %2)

Parameters:
%1 = Error code 1
%2 = Error code 2
Definitions:
An attempt to read a data block, e.g. a drive boot file, from the file system has failed. The data block or the file system
is damaged.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
If the error occurred during power-up, i.e. it is probably connected to a drive boot file, delete all boot files and load them
back into the control from the back-up copy.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
892
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents