Tm54F: Temperature Fault Threshold Exceeded; Tm54F: Temperature Alarm Threshold Exceeded; Tm54F: Error During Internal Communication - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

SINAMICS alarms
235053
<location>TM54F: Temperature fault threshold exceeded
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The temperature measured using the temperature sensing on the TM54F has exceeded the threshold value to initiate
this fault.
As fault response fail-safe input terminal signals are transferred to the motion monitoring functions.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- allow the TM54F to cool down.
- carry out safe acknowledgement (p10006).
235054
<location>TM54F: Temperature alarm threshold exceeded
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
The temperature measured using the temperature sensing on the TM54F has exceeded the threshold value to initiate
this alarm.
Remedy:
- allow the TM54F to cool down.
- carry out safe acknowledgement (p10006).
235075
<location>TM54F: Error during internal communication
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
An internal communications error has occurred in the Terminal Module 54F (TM54F).
This alarm can also occur if the TM54F exists and no safety function has yet been parameterized.
Alarm value (r2124, interpret decimal):
Only for internal Siemens diagnostics.
Remedy:
For internal communication errors:
- check the electrical cabinet design and cable routing for EMC compliance
- upgrade the software on the TM54F.
- contact the Hotline.
- replace the TM54F.
If TM54F exists and no safety function has yet been parameterized:
- None necessary. The alarm disappears automatically after a safety function has been parameterized.
852
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents