Siemens Simatic Ident Function Manual page 92

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Setting parameters for blocks
3.5 Programming the Ident profile
Byte
Value
Byte 10
param
92
RFID system Meaning
...
...
0xC8
1400 ms standby time
RF200,
Setting for the RFID mode and presence check
RF300,
Bit
Description
MOBY D,
7 ... 5
Presence check and transponder control:
MOBY U
4
To be assigned the value "0x00".
3 ... 0
RFID mode:
Value of bit 3 ... 0
Value
Operating
of bit 3
mode
... 0
0x00
Reserved
0x01
MOBY I
0x05
MOBY U/D,
RF200, RF300
- without multi-
tag mode
0x06
MOBY U - with
mulititag mode
(FB 55)
0x07
MOBY D,
RF300 - with
mulititag mode
(FB 55)
Note: Note that after a parameter change the CM must be restarted.
0x00 = Operation without presence check
0x01 = Operation with presence check
Antenna is permanently switched on.
0x04 = Operation without presence check
Antenna is switched off. The antenna is only switched on when one
of the following commands is sent: Read, Write, Init, Tag-Status
0x05 = Without multitag mode with communications module ASM
475, ASM 456, RF170C, RF180C
0x06 = With multitag mode with communications module ASM 475,
ASM 456, RF170C, RF180C
Only with MOBY U
Description
reserved for the setting with the switch or GSD pa-
rameter assignment
If RF300 readers of the 2nd generation are to be oper-
ated in MOBY I mode, the value = 0x01 must be set.
Short "INIT" (only the "param" and "option_1" parame-
ters are transferred to the reader).
ASM 475, ASM 456, RF170C, RF180C
Parameter setting with Multitag > 1 and more than
one transponder in the antenna field: the UID pa-
rameter must be supplied with the transponder ID.
Parameter setting with Multitag = 1 and only one
transponder in the antenna field: the UID parameter
can be supplied with the correct transponder ID or
zero.
ASM 475, ASM 456, RF170C, RF180C
ASM 475, ASM 456, RF170C, RF180C
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04

Hide quick links:

Advertisement

Table of Contents
loading