Siemens Simatic Ident Function Manual page 14

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Setting parameters for blocks
3.1 Overview of the Ident library
Position
Status blocks
Reset blocks
PLC data types
System data types
Status data types
14
Block name
Ident_Profile
Reader_Status
Tag_Status
Reset_MOBY_D
Reset_MOBY_U
Reset_MV
Reset_RF200
Reset_RF300
Reset_RF600
Reset_Univ
IID_HW_CONNECT
IID_CMD_STRUCT
IID_READSTAT_
81_RF2_3_U
IID_READSTAT_
84_MOBY_U
IID_READSTAT_
86_RF300
IID_READSTAT_
87_RF600
IID_READSTAT_
88_RF600
IID_READSTAT_
89_RF68xR
IID_READSTAT_
A0_A1_RF600
IID_CM_STATUS_A2
IID_TAG_STATUS_
04_RF300
IID_TAG_STATUS_
80_MOBY_U
IID_TAG_STATUS_
82_RF300
IID_TAG_STATUS_
83_ISO
IID_TAG_STATUS_
84_RF600
IID_TAG_STATUS_
85_RF600
Ident profile and Ident blocks, standard function for Ident systems
Description
These blocks are available for experts to be
able to include complex command structures
in their own program sequence. It is also pos-
sible to use repeat commands and chaining.
Using the status blocks you obtain information
on the reader or transponder.
Using these blocks, it is simple to program
communication with the Ident systems.
The reset blocks are used for simple initializa-
tion of the Ident systems if the "Re-
set_Reader" block is not supported by the
Ident system.
Data type for all blocks for physical addressing
of communications modules and readers and
for synchronizing the function blocks used for
each reader.
Data type for the Ident profile for setting the
command parameters.
Data types for the result of "Reader_status"
with the relevant attribute.
The data types help you to interpret the data
received from the reader and to process the
data further directly without data type conver-
sions.
Data types for the result of "Tag_status" with
the relevant attribute.
The data types help you to interpret the data
received from the reader and to process the
data further directly without data type conver-
sions.
Function Manual, 10/2018, C79000-G8976-C387-04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents