3.4.2.7

Set_Param

With the "Set_Param" block, you can change UHF parameters on an
RF18xC/RF61xR/RF68xR during runtime (e.g. the antenna power).
Note
Settings saved only temporarily
Note that the parameters in the "Set_Param" block are only stored temporarily. If the power
for the reader is interrupted, the stored values are lost and must be set again.
Figure 3-19
Table 3- 23
Parameter
PARMID
VALUE
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
"Set_Param" block
Explanation of the "Set_Param" block
Data type
DWORD
DWORD
Default values
Description
0x00
Parameter identifier
0x00
Parameter value
Setting parameters for blocks
3.4 Programming Ident blocks