Table 3- 66
Put_SET_ANT
Mode
Length
Put_END
UID
Mode
Length
Table 3- 67
Parameter
CMD
OFFSETBUFFER
EPCID_UID
LEN_ID
LEN_DATA
PSWD
TXREF
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
Data structure of the PUT command
Switches the antenna of the reader off and on.
RF200/RF300, MOBY U/D:
0x01 ≙ antenna on
0x02 ≙ antenna off
RF600:
Bit 0 ≙ ANT 1 / internal antenna (1 = on)
Bit 1 ≙ ANT 2 / external antenna (1 = on)
Bit 4 ≙ TagList (0 = initialize, 1 = continue working with the existing list)
3
Terminates communication with a transponder (MOBY U only).
UID of the transponder
0x00 ≙ end processing of the transponder
0x01 ≙ processing pause of the transponder
11
WRITE-ID (RF61xR/RF68xR only)
Value / description
0x67
Offset in the "TXREF" send buffer
Previous EPC-ID
0x00 ≙ unspecified single tag access
Length of the previous EPC-ID (2-62 bytes)
0x00 ≙ unspecified single tag access
Length of the new EPC-ID
Password
0x00 ≙ no password
New EPC-ID