Siemens Simatic Ident Function Manual page 37

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Name
UID[20]
UID[21]
UID[22]
UID[23]
UID[24]
UID[25]
UID[26]
UID[27]
UID[28]
UID[29]
reserved1
Data
Note
Number of handle IDs
"number_MDS" specifies the number of handle IDs (1 to 29) transferred with the
"INVENTORY" block. To receive the handle IDs of all transponders located in the antenna
field, it may be necessary to run the "INVENTORY" block again with ATTRIBUTE "0x82".
Table 3- 15
ATTRIBUTE "0x85" (data type "IID_INVENT_85_RF600")
Name
reserved
number MDS
ID
ID[1]
Handle
Handle[1]
Handle[2]
Handle[3]
Handle[4]
Handle[5]
Handle[6]
Handle[7]
Handle[8]
EPC
EPC[1]
EPC[2]
EPC[3]
EPC[4]
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
Type
Comment
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
"IID_IN_I_8BYTE"
DWORD
ARRAY[1..222] of
BYTE
Type
Comment
BYTE
STRUCT
Number of MDS
BYTE
BYTE
ARRAY[1..8] of BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
ARRAY[1..12] of
BYTE
BYTE
BYTE
BYTE
BYTE
Setting parameters for blocks
3.4 Programming Ident blocks
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents