Figure 3-37
Sequence of the repeat command without command transfer:
This sequence is only possible if the command involved has already been transferred.
1. If applicable, enable presence mode (with RF61xR/RF68xR).
2. Set the "RPTCMD" input parameter.
The Repeat command is activated on the reader.
3. The reader confirms activation with the output parameter "RPTACT" of the Ident profile.
The confirmation is made only after the first command has been executed.
If the reader does not support the Repeat command, "RPTACT" remains inactive. If
"EXECUTE" is nevertheless set, the error "0xE7FE0900" is output after a timeout of 10
seconds.
4. You can read out the individual results by repeatedly setting the "EXECUTE" input
parameter.
Figure 3-38
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
Sequence of the repeat command with simultaneous command transfer
Sequence of the repeat command without command transfer
3.5 Programming the Ident profile
Setting parameters for blocks
109