Reset_Rf300 - Siemens Simatic Ident Function Manual

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

3.4.3.5

Reset_RF300

Figure 3-27
Table 3- 32
Parameter
TAG_CONTROL
TAG_TYPE
RF_POWER
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
"Reset_RF300" block
Explanation of the "Reset_RF300" block
Data type
Byte
Byte
Byte
Default values
Description
1
Presence check
0 = Off
1 = on
4 = presence (antenna is off. The
antenna is turned on only when a
Read or Write command is sent.)
0
Transponder type:
1 = every ISO transponder
0 = RF300 transponder
0
Output power; only relevant for
RF380R
RF power from 0.5 W to 2 W in incre-
ments of 0.25 W (range of values:
0x02 ... 0x08).
Default value: 0x00 ≙ 1.25 W.
This setting is not necessary with the
RF380R readers of the 2nd generation
(6GT2801-3BAx0) because the power
limits are optimized automatically
depending on the reader-transponder
distance.
Setting parameters for blocks
3.4 Programming Ident blocks
55