Net Shoot Setting menu
The [Net Shoot Setting] menu sets up net shoot parameters. Click [Net Shooting Set-
ting] on the [Initial Setting] menu to show the [Net Shoot Setting] menu.
Net Diameter
Tilt Interlock
Net Plot Corr-LYR1
Net Plot Corr-LYR2
Net Plot Corr-LYR3
Net Plot Corr-LYR4
Net Plot Corr-LYR5
[Net Diameter]: Sets net diameter in increments of 10 meters. The setting range is
200 m to 1000 m.
[Tilt Interlock]: Turns on/off interlocking of diameter of net course mark with tilt angle.
[Net Plot Corr-LYR1] - [Net Plot Corr-LYR5]: The movement of the net during net
shooting is plotted using water current speed and direction fed from a current indica-
tor. The current indicator feeds that data for three depths (layers), thus net movement
will be different at each layer. Determine degree of difference among layers consider-
ing net, sea conditions, etc. If 50% is set, for example, the net movement plot mark
moves at speed of 50% of water current speed.
Stabilization menu
The [Stabilization] menu compensates for the affects of pitching and rolling. Click [Sta-
bilization] on Initial [Setting menu] to show the [Stabilization] menu. Requires a motion
sensor.
Stabilization
F8
Pitch Angle Cor
Roll Angle Corr
Sensor
[Stabilization]: Turns stabilization on/off.
Note: The default function of the F9 key turns stabilization on/off.
[Pitch Angle Cor]: Offsets the pitch angle error generated by the motion sensor.
[Roll Angle Cor]: Offsets the roll angle error generated by the motion sensor.
Net Shoot Setting
: 500m
: ON
: 50%
: 50%
: 50%
: 50%
: 50%
Stabilization
: ON
: 0.0
: 0.0
: Standard