Furuno FSV-25 Operator's Manual page 114

Color scanning sonar
Hide thumbs Also See for FSV-25:
Table of Contents

Advertisement

6. OTHERS MENU
Net SONDE Setting menu
The [Net SONDE Setting] menu sets up the net sonde. Click [Net SONDE Setting] on
the [Initial Setting] menu to show the [Net SONDE Setting] menu.
[Number Of XMTR]: Sets number of transmitter units used, from 0 to 10. When the
total value of [XMTR Distance] is smaller than the setting value of [Net Length], max.
10 transmitter units can be used.
[XMTR Distance]: Sets the distance between transmitters. Select this item then push
the left button to set the distances.
[Net Length]: Sets net length in increments of 100 m. The minimum value changes
according to [Number of XMTR] and [XMTR Distance].
[Depth Display]: Selects which sonde depth data to show, a
shown in the right figure. Select this item and push the left button
to select net sondes. The check mark shows current selection
(Max. 3).
[Display Style]: Selects the display format of the net depth, Nu-
meric or Graph.
[Depth Graph Range]: Sets the depth range of the SONDE
graph. The settings 50 m, 100 m, 150 m, 200 m.
6-14
Net SONDE Setting
Number of XMTR*
XMTR Distance ...
Net Length
Depth Display ...
Display Style
Depth Graph Range
*Setting cannot be adjusted after the net is thrown.
XMTR Distance
End of Net to S1
S1->S2
S2->S3
S3->S4
Quit
: 3
: 1800m
: Numeric
: 100m
Quit
: 400m
: 400m
: 400m
: 400m
Quit
Cancel
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-2s

Table of Contents