A:TERMINAL STATUS CODE--
(1) Terminal Status 1
The display format is as follows:
F 0 1 -
A
B C
A:
Date format
0 = Month-Day-Year
1 = Day-Month-Year
2 = Year-Month-Day
Decimal Point Position
B:
DISPLAY
0
0
1
.0
2
.00
3
.000
Change condition:
1. The sales total memory must be blank
2. When the register has registration data, must make sure all Reports are
reset and the grand total is blank.
Rounding for multiplication sales.
C:
0 = Round Off (5/4)
1 = Round Up
2 = Discarding
D:
When EJ is full, clear all EJ information automatic or by manual.
0 = Clear the EJ by manual
1 = Auto clear the EJ
Note: When EJ is full, choose clear the EJ by manual, ECR will not store the
new transaction to electronic journal if haven't done clear operation.
1 =
Terminal Status 1
2 =
Terminal Status 2
3 =
Terminal Status 3
4 =
Terminal Status 4
5 =
Terminal Status 5
6 =
Terminal Status 6
7 =
Terminal Status 7
8 =
Machine Number Preset.
9 =
Receipt Consecutive Number Preset
10=
High Amount Lock-out Preset (HALO)
11=
Total in Drawer Limit
12=
Graphic logo Selection
13=
Clerk/receipt ON/OFF key Selection
D E
(MM-DD-YY)
(DD-MM-YY)
(YY-MM-DD)
PRINTING
12345678
1234567.8
123456.78
12345.678
22
 Default
 Default
 Default
 Default