Switching On Quick-Stop - DURKOPP ADLER 911-210 Operating Instructions Manual

Hide thumbs Also See for 911-210:
Table of Contents

Advertisement

Operation

4.3 Switching on Quick-stop

The Quick-stop switch (1) can be used to immediately stop all working
steps on the machine, e.g. after an operating mistake.
Fig. 4: Switching on Quick-stop
(1) - Quick-stop switch
Stopping working steps via Quick-stop
To stop the working steps via Quick-stop:
1. Press the Quick-stop switch (1).
 All working steps on the machine are immediately stopped.
Switching off the power to the machine
1. Turn the main switch (2) to the left into the 0 position.
 All drives and the control are immediately disconnected from the
Operating Instructions 911-210 - 04.0 - 11/2016
WARNING
Risk of injury from sharp and moving parts!
Puncture or crushing possible.
Switch off the machine prior to maintenance or
cleaning work
mains grid.
(2) - Main switch
17