3 SPECIFICATIONS AND FUNCTIONS

3.4.3 List of input/output signal details

Signal name
Near-point dog signal
Speed-position switching signal
Common
Zero signal
Zero signal common
External power input (0V)
External power input (+24V)
Pulse output F
Pulse output R
Pulse output common
Deviation counter clear
Deviation counter clear common
3 - 10
The details of each QD70 external device connection connector are shown below:
Pin No.
Symbol
A10
B10
DOG
A9
B9
A12
B12
CHG
A11
B11
A8
B8
COM
A19
B19
PGO
A17
B17
A20
B20
PGO COM • Common for zero signal.
A18
B18
A1 (COM1)
24G
B1 (COM1)
+24V
A7
B7
PULSE F
A4
B4
A5
B5
PULSE R
A2
B2
A6
B6
PULSE
A3
B3
COM
A15
B15
CLEAR
A13
B13
A16
B16
CLEAR
A14
B14
COM
(Negative logic is selected by I/O signal logic selection)
• This signal is used for detecting the near-point dog during OPR control.
• The near-point dog OFF
• The near-point dog ON
• This signal is input as a control switching signal in speed-position switching
control.
• Common for near-point dog signal and speed-position switching control
signal.
• Input the zero signal for OPR control.
Use the pulse encoder's zero signal and so on.
• Also use this signal when the OPR method is the stopper method and the
OPR complete is input from an external source.
• The OP is detected at the falling edge.
• These signals are used to input 24VDC power for driving the pulse output
circuit. (Common to all axes)
• This signal is used to output command pulses to the open collector
compatible drive unit.
CW/CCW mode: CW, PULSE/SIGN mode: PULSE
• This signal is used to output command pulses to the open collector
compatible drive unit.
CW/CCW mode: CCW, PULSE/SIGN mode: SIGN
• Common for pulse output F and pulse output R.
• This signal is output during machine OPR control.
(Example) When carry out OPR control with stopper 2 .
Speed
OPR. 4
OPR speed
Pr. 6 Bias
speed at star
Near-point dog
CLEAR
• The output time of the deviation counter clear signal is set in " Pr. 8 Deviation
counter clear signal output time".
• Use the drive unit that can reset the droop pulse amount in the internal
deviation counter when the QD70 turns this signal ON.
(Note) The deviation counter clear is a signal output by the QD70 during
machine OPR control. It cannot be output randomly.
• Common for deviation counter clear
Signal details
ON is detected at the rising edge.
OFF is detected at the falling edge.
OPR. 5
Creep speed
t
Zero signal
Pr. 8
Deviation counter
clear signal output time
After feed pulse output stops
MELSEC-Q
Stopper
Time
3 - 10