Mitsubishi Q Series User Manual page 34

Positioning module, programmable logic controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS AND FUNCTIONS
3.3.3 Details of output signals (PLC CPU
Device No.
Y0
PLC READY
Y8
Axis 1
Positioning start
Y9
Axis 2
YA
Axis 3
YB
Axis 4
YC
Axis 5
YD
Axis 6
YE
Axis 7
YF
Axis 8
Y10
Axis 1
Axis stop
Y11
Axis 2
Y12
Axis 3
Y13
Axis 4
Y14
Axis 5
Y15
Axis 6
Y16
Axis 7
Y17
Axis 8
Y18
Axis 1
JOG start
Y19
Axis 2
Y1A
Axis 3
Y1B
Axis 4
Y1C
Axis 5
Y1D
Axis 6
Y1E
Axis 7
Y1F
Axis 8
3 - 6
The ON/OFF timing and conditions of the output signals are shown below.
Signal name
OFF:
PLC READY OFF
ON:
PLC READY ON
OFF:
Positioning start not
requested
ON:
Positioning start
requested
OFF:
Axis stop not
requested
ON:
Axis stop requested
OFF:
JOG not started
ON:
JOG started
QD70)
(a) This signal notifies the QD70 that the PLC CPU is normal.
• It is turned ON/OFF with the sequence program.
• The PLC READY signal is turned ON during positioning
control, OPR control and JOG operation.
(b) When parameters and OPR data are changed, the PLC READY
signal is turned OFF.
(c) The following processes are carried out when the PLC READY
signal turns from OFF to ON.
• The parameter and OPR data setting range is checked.
• The module READY signal [X0] turns ON.
(d) The following processes are carried out when the PLC READY
signal turns from ON to OFF.
In these cases, the OFF time should be set to 100ms or more.
• The module READY signal [X0] turns OFF.
• The operating axis stops.
• OPR control and positioning control is started.
• The positioning start signal is valid at the rising edge, and the
operation is started.
• When the positioning start signal turns ON during BUSY, the
operation starting warning will occur (warning code: 10).
• When the axis stop signal turns ON, the OPR control, positioning
control and JOG operation. In these cases, the ON time should be
set to 4ms or more.
• Turning ON the axis stop signal during operation decelerates the
axis to a stop. At this time, " Md. 4 Axis operation status" changes
from "Deceleration (Axis Stop ON)" to "Stopped".
• When the JOG start signal is ON, JOG operation will be carried
out at the " JOG. 1 JOG speed". When the JOG start signal turns
OFF, the operation will decelerate and stop. At this time, " Md. 4
Axis operation status" changes from "Deceleration (JOG Start
OFF)" to "Standby".
• Set the rotation direction in " JOG. 4 JOG direction flag". (Refer to
Chapter 10.)
MELSEC-Q
Description
3 - 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd70p4Qd70Qd70p8Sw1d5c-qptu-eGx configurator-pt

Table of Contents