Graphic Command
Graphic Print
[ESC+G]
BMP File Print
[ESC+GM]
[ESC+GP]
PCX File Print
Parent topic
Part 1 SBPL Commands
[ESC+G] Graphic Print
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the print of graphic.
[Format]
<G>abbbcccn...n
•
Parameter
a [Data specification by HEX and BIN]
H : Hex data
Specify graphic data as 2 characters of ASCII 0-F which is equal to 8 dots,
output it as hex code corresponding to ASCII.
B : Binary data
Specify graphic data as one byte of binary which is equal to 8 dots.
b [Specification of crosswise graphic area per byte] = Valid range: Refer to the table below.
c [Specification of lengthwise graphic area per byte] = Valid range: Refer to the table below.
n [Graphic data]
[Coding Example 1]
[H: HEX data] is specified for [Data specification by HEX and BIN]
[□] is printed with the below specification.
<A>
<V>50<H>50
<G>H001001<46463831383138313831383138314646>
<Q>1
<Z>
[Coding Example 2]
[B: Binary data] is specified as [Data specification by HEX and BIN]
[□] is printed with the below specification.
<A>
<V>50<H>50
<G>B001001<FF818181818181FF>
<Q>1
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
16
321
G
<47>
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
16
Parameter
abbbcccn...n