[ESC+2D50] DataMatrix (ECC200)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying DataMatrix Code (ECC200).
[Format] (Setup part)
<2D50>,aa,bb,ccc,ddd
•
Parameter
a [Horizontal cell size] = Valid Range : 01 to 99 dots
b [Vertical cell size] = Valid Range : 01 to 99 dots
c [Number of cell in one line]
Valid Range : 010 to 144
000 : (Auto-setting)
d [Number of cell lines]
Valid Range : 008 to 144
000 : (Auto-setting)
[Format] (Data part)
<DN>mmmm,n...n
•
Parameter
m [Number of data] = Valid Range : 1 to 3116
n [Print data] = Data
* When print 7EH, specify "7EH, 7EH"
* If Parameter other than above is specified or print data does not match, printing is not performed.
[Coding Example]
Horizontal cell size: 3 dots, Vertical cell size: 3 dots
<A>
<V>100<H>200<2D50>,03,03,000,000
<DN>0010,0123456789
<Z>
ESC
2D50
<1B>
<32>
<44>
16
16
Nil
When the power is OFF
Valid range within items
Valid range between items
270
<35>
<30>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
,aa,bb,ccc,ddd