[Esc+2D51] Gs1 Datamatrix - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[ESC+2D51] GS1 DataMatrix

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying GS1 DataMatrix Code.
[Format] (Setup part)
<2D51>,aa,bb,ccc,ddd
Parameter
a [Horizontal cell size] = Valid Range   :   01 to 99 dots
b [Vertical cell size] = Valid Range   :   01 to 99 dots
c [Number of cell in one line]
      Valid Range   :   010 to 144
      000   :   (Auto-setting)
d [Number of cell lines]
      Valid Range   :   008 to 144
      000   :   (Auto-setting)
[Format] (Data part)
<DN>mmmm,n...n
Parameter
m [Number of data] = Valid Range   :   1 to 3116
n [Print data] = Data
      * When print 7EH, specify [7EH, 7EH].
      * When print 1BH, specify [1BH, 1BH].
      * When print FNC1, specify [1BH, 31H].
      * If Parameter other than above is specified or print data do not match, print is not secured.
[Coding Example]
Horizontal cell size: 3 dots, Vertical cell size: 3 dots
<A>
<V>100<H>200<2D51>,03,03,000,000
<DN>0014, <1B>
<Q>2
<Z>
* <1B>
specifies character code "1BH".
16
ESC
2D51
<1B>
<32>
16
16
Nil
When the power is OFF
Valid range within items
Valid range between items
1100123456789
16
<44>
<35>
<31>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
274