1. Product characteristics
Passive infrared presence detector for ceiling installation
Circular detection area 360° to Ø 24 m (452 m
Restriction of detection area with cover clips
Automatic presence- and brightness-dependent control
for lighting
Mixed light measurement suitable for fluorescent lamps
(FL/PL/ESL), halogen/incandescent lamps and LEDs
Channel A light: relay, 230 V
Choice of fully or semi-automatic operation
Brightness switching value configurable, teach-in
function
Reduction of time delay when briefly present (short-term
presence)
Connection option for push buttons or switches for
manual switching with automatic detection of push
button/switch
Pulse function for staircase light time switch
Time delay configurable
Detection sensitivity configurable
Ready for immediate use due to factory presetting
Test mode for checking function and detection area
Extension of detection area via master/slave or master/
master switching, a maximum of 10 detectors can be
switched in parallel with each other
Ceiling installation in flush-mounted box
Ceiling installation possible with back box (optional)
User remote control theSenda S (optional)
Management remote control SendoPro (optional)
Installation remote control theSenda P (optional)
2. Safety
WARNING
Danger of death through electric shock or fire!
 Installation should only be carried out by a pro-
fessional electrician!
Work on electrical systems may only be carried out by
electricians or by instructed persons under the leader-
ship and supervision of an electrician in accordance with
the technical regulations applying to electricity!
Comply with the country-specific safety regulations for
work on electrical systems! Ensure absence of voltage in
the cable before installation!
The device is maintenance-free. If the device is opened
or penetrated with any objects the guarantee lapses.
3. Intended use
307245
1103105201
The presence detector is intended for interior installation. The
presence detector is exclusively intended for the use as con-
tractually agreed between the manufacturer and the user. Any
other use is considered to be unacceptable. The manufacturer
does not accept liability for any resulting damages.
4. Function
The presence detector is primarily used in entrance halls,
garages, store rooms, offices and schools, as well as in homes,
for easy and energy-efficient control of lighting. The switch
contact „light" switches lighting on with presence and insuf-
)
2
ficient brightness, and off with absence or sufficient bright-
ness. The light can also be switched on/off manually using
push buttons or switches.
Functional description
 Mixed light measurement
 Presence detection
 Artificial light
 Push button for manual lighting control
 Incident daylight
Settings on theRonda P360-100
 Brightness set point value (lux)
 Lighting time delay
 Mechanical safety lock
Light channel A
Switching response is controlled by presence and brightness.
The switch contact closes during darkness and when some-
one is present. It opens with a delay when there is brightness
or when no one is present.
Time delay
The time delay enables delayed switching off of lighting after
the room is vacated. The time delay is adjustable in a range
of 10 s to 60 min. If someone goes into an unoccupied room
only briefly and leaves it within 30 seconds, then the light
shuts off prematurely after 2 minutes (short-term presence).
1

Advertisement

Table of Contents
loading

Summary of Contents for Theben theRonda P360-100 M UP WH

  • Page 1 The presence detector is intended for interior installation. The Presence detector presence detector is exclusively intended for the use as con- theRonda P360-100 M UP WH tractually agreed between the manufacturer and the user. Any other use is considered to be unacceptable. The manufacturer...
  • Page 2: Detection Area

    Push button control Installation Moving persons Moving persons Seated persons: height (A) Frontal (r) Across (t) The lighting can be manually switched at any time via a push button or switch. If the light is switched on manually, it 2,0 m 28 m Ø...
  • Page 3 7. Switching The presence detectors can be combined as master and slave: master in individual switching, master in parallel switching, master-slave parallel switching. Several push buttons can connected to one control input. Illuminated push buttons can only be used with neutral con- ductor connection.
  • Page 4 Parameters and control commands via remote Master 1 Master 2 control L’ L’ The following parameters can be queried or changed via • One master with individual brightness measurement per the remote control for support during installation as well as lighting group servicing: •...
  • Page 5: Configuration Type

    Value range below the switching value, the light switches on when a pre- sence is detected (in configuration type fully automatic). Automatic detection of push button or switch. A signal that auto is present for than 0.7 s is detected as a push button. Longer Value range signals are evaluated as a switch.
  • Page 6: Technical Data

    10. Technical data The control command teach-in can be adopted with the „SendoPro 868-A“ management remote control or with the „theSenda P“ installation remote control via the button. Operating voltage 110-230 V AC + 10 % / - 15% Frequency 50-60 Hz Factory settings Upstream protection device:...
  • Page 7: Dimensional Drawings

    Theben HTS AG therefore guarantees perfect Details > www.theben.de operation when used correctly. Should a fault occur, however, Theben HTS AG will fulfil the guarantee within the scope of the general terms and conditions. DE (ceiling installation) box 73A Please note in particular: Item No.: 9070917...
  • Page 8 12. Contact SendoPro 868-A Item No.: 9070675 Details > www.theben.de Theben HTS AG Im Langhag 7b 8307 Effretikon SWITZERLAND Phone +41 52 355 17 00 Fax +41 52 355 17 01 Hotline Phone +41 52 355 17 27 theSenda S hotline@theben-hts.ch...

This manual is also suitable for:

Theronda p360-100 m up gr

Table of Contents