COPY OF SAFETY LABEL
This is a copy of the labels that accompany each LRI4E Gas Insert. We
have printed a copy of the contents here for your review.
Duplicate Serial number/Copie No de série
Listed/Nom:
VENTED GAS FIREPLACE HEATER /
Certified to / Certifi :
é ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
C# 4001172
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
Minimum Clearances to Combustibles
from Insert/Dégagements min. combustibles
Side wall / mur latéral
A
8"
(203mm)
Ceiling / Plafond
B
60"
(1524mm)
Mantel / Manteau
C
35"
(889mm)
Min. Alcove Width/
Largeur min. alcôve
K
54"
(1372mm)
Max. Alcove Depth/
Prof. max. alcôve
L
36"
(914mm)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details.
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Cet appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, conformément au National Fuel Gas
Code ANSI Z223.1, ou au CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique.
Cet appareil n'est pas convertible pour être utilisé avec d'autres gaz, sauf si une trousse de conversion certifiée est utilisée.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une maison préfabriquée ou
mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Cet
appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 399-100) Follow installation instructions.
À utiliser uniquement avec l'écran de sécurité (Pièce n°399-100). Suivre les consignes d'installation.
Electrical supply / Alimentation électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 70.27%
RENDEMENT
Propane Gas / Gaz propane 69.36%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
For the State of Massachusetts, installation and repair
Part #:
919-934a
must be done by a plumber or gas fitter licensed in
the Commonwealth of Massachusetts.
Colour:
Black on grey except what is highlighted is printed red
Size:
(File at 100%) 6.45"W x 8.66" H
Material:
2 ml silver matt polyester (DPM SMS)
For the State of Massachusetts, flexible connectors
Oct 15/2018:
Created draft
shall not exceed 36 inches in length.
Nov. 05/18:
New Serial #
Jan 23/19:
Rev A - Remodeled decal + added ETL logo at the bottom
For the State of Massachusetts, the appliances indi-
vidual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation
of a carbon monoxide alarm in accordance with NFPA
720 and a CO alarm with battery back up in the same
room where the gas appliance is installed.
FOYER AU GAZ VENTILÉ
NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No. / No de série
MODEL LRI4E-NG11
FONCTIONNANT AU GAZ NATUREL
Pression d'alimentation minimale
5"
WC
(1.25 kpa)
Pression de sortie (manifold) - basse
1.6"
WC
(0.41 kpa)
Pression de sortie (manifold) - max.
3.5"
WC
(0.87 kpa)
Taille de l'orifice
#37
DMS
D bit calorifique minimal
é
22,000
Btu/h
(6.45 kW)
D bit calorifique maximal
é
31,000
Btu/h
(9.09 kW)
MODEL LRI4E-LP11
FONCTIONNANT AU GAZ PROPANE
11"
WC
(2.73 kpa)
Pression d'alimentation minimale
Pression de sortie (manifold) - basse
6.4"
WC
(1.59 kpa)
10"
WC
(2.48 kpa)
Pression de sortie (manifold) - max.
Taille de l'orifice
#53
DMS
D bit calorifique minimal
é
26,000
Btu/h (7.62 kW)
D bit calorifique maximal
é
31,000
Btu/h (9.09 kW)
Mantel Clearances / Dégagements manteau
Min. Hearth Width /
Largeur min. âtre
Min. Hearth Length/
A
G
Longueur min. âtre
Max. Mantle Depth/
L
B
Prof. max. manteau
C
MADE IN CANADA /FABRIQUÉ AU CANADA
D
E
K
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
À utiliser uniquement avec les portes en verre certifiées avec l'appareil.
DECAL LOCATION
NOTE: Regency units are constantly being improved. Check the label on
the unit and if there is a difference, the label on the unit is the correct one.
481
DO NOT REMOVE THIS LABEL /
481
MODÈLE LRI4E-NG11
MODÈLE LRI4E-LP11
D
14"
(356mm)
E
40"
(1016mm)
G
12"
(305mm)
Regency Fireplace Products
Delta BC, CANADA
Fan Part # 911-071/Pièce ventilateur
919-934a
safety decal
Remove faceplate from front of unit (see manual)
Once the faceplate is removed the rating plate will
be located below the glass (see picture).
DO NOT REMOVE THE DECAL FROM THE UNIT
LRI4E / HRI4E-11 Direct Vent Gas Insert
|
9