safety decal
COPY OF SAFETY LABEL
This is a copy of the labels that accompany each HRI4E Gas Insert. We
have printed a copy of the contents here for your review.
Listed/Nom:
VENTED GAS FIREPLACE HEATER /
Certified to / Certifi :
é ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C#4001172
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
Minimum Clearances to Combustibles
from Insert
Side wall
A
8"
(203mm)
Ceiling
B
60"
(1524mm)
Mantel
C
35"
(889mm)
Min. Alcove Width
K
54"
(1372mm)
Max. Alcove Depth
L
36"
(914mm)
Regency Fireplace Products,
Delta BC, CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique.
Cet appareil n'est pas convertible pour être utilisé avec d'autres gaz, sauf si une trousse de conversion certifiée est utilisée.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une maison préfabriquée ou
mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Cet
appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 399-100) Follow installation instructions. Pour l'utilisation seulement avec l'écran de sécurité (Pièce n 399-100)
Electrical supply / Alimentation électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. /
FOYER AU GAZ VENTILÉ - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 70.27%
RENDEMENT
Propane Gas / Gaz propane 69.36%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #:
919-935a
Colour: Black on grey except what is highlighted is printed red
Size:
(File at 100%) 6.688''W x 8.588''H
Material:
2 ml silver matt polyester (DPM SMS)
For the State of Massachusetts, installation and repair must be done by a plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
Oct.15/2018:
Created draft
Nov.05/18:
New Serial #
Jan.14/19:
Updated efficiencies + orifice size #
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
Jan 23/19:
Rev A - Remodeled decal + added ETL logo at the bottom
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and
a CO alarm with battery back up in the same room where the gas appliance is installed.
10
|
LRI4E / HRI4E-11 Direct Vent Gas Insert
Duplicate Serial number
FOYER AU GAZ VENTILÉ
NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No. / No de série
MODÈLE HRI4E- NG11
MODEL HRI4E-NG11
FONCTIONNANT AU GAZ NATUREL
Pression d'alimentation minimale
5"
WC
(1.25 kpa)
Pression de sortie (manifold)
1.6"
WC
(0.41 kpa)
3.5"
WC
(0.87 kpa)
Pression de sortie (manifold)
#37
DMS
Taille de l'orifice
22,000
Btu/h
(6.45 kW)
D bit calorifique minimal
é
31,000
Btu/h
(9.09 kW)
D bit calorifique maximal
é
MODÈLE HRI4E- LP11
MODEL HRI4E-LP11
FONCTIONNANT AU GAZ PROPANE
Pression d'alimentation minimale
11"
WC
(2.73 kpa)
Pression de sortie (manifold)
6.4"
WC
(1.59 kpa)
10"
WC
(2.48 kpa)
Pression de sortie (manifold)
Taille de l'orifice
#53
DMS
26,000
Btu/h (7.62 kW)
D bit calorifique minimal
é
31,000
Btu/h (9.09 kW)
D bit calorifique maximal
é
Mantel Clearances/
Min. Hearth Width
Min. Hearth Length
Max. Mantle Depth
.
A
A
G
G
L
L
B
B
MADE IN CANADA /FABRIQUÉ AU CANADA
C
D
D
E
E
K
K
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
NOTE: Regency units are constantly being improved. Check the label on
the unit and if there is a difference, the label on the unit is the correct one.
486
DO NOT REMOVE THIS LABEL /
486
basse
-
max.
-
basse
-
max.
-
Dégagements manteau
D
14"
(356mm)
E
40"
(1016mm)
G
12"
(305mm)
o
Fan/Ventilateur Part # 911-071
919-935a
This appliance is only for use with the type of gas indicated on the
plate and may be installed in an aftermarket, permanently lo
manufactured (mobile) home where not prohibited by local codes
owner's manual for details
Cet appareil doit être utilize uniquement avec le type de gaz indiqué
plaque signalétique. Cet appareil peut être installé dans une m
préfabriquée ou mobile (É.-U. seulement) installée à demeure
règlements locaux le permettent. Voir la notice de l'utilisateur pou
de renseignements.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz.