Chapter 7 System Specifications; C2000 Model Specifications; C4000 Model Specifications - Juniper C2000 Hardware Manual

Hide thumbs Also See for C2000:
Table of Contents

Advertisement

Chapter 7
System Specifications

C2000 Model Specifications

Table 6: C2000 Model Specifications
Category
Weight
Dimensions
Environmental Requirements
Temperature
Relative humidity
Heat Dissipation
AC Input
Power required
AC line frequency
Power
Space Requirements
Safety Agency Certification
This chapter lists the system specifications, requirements, and certifications for the
system. Topics include:
C2000 Model Specifications

C4000 Model Specifications

Specification
33 lb (15 kg)
3.5 (H) x 16.7 (W) x 16.2 (D) inches
8.89 (H) x 42.42 (W) x 41.15 (D) cm
Operating: 50° to 104° F (10° to 40° C)
Storage: –40° to 158° F (–40° ˚ to 70° C)
Operating: 8% to 90% (noncondensing)
Storage: 5% to 95% (noncondensing)
500 W, 1706 BTU/hour maximum
100-240 VAC @ –5 A
50-60 Hz
500 W
3 feet (90 cm) behind system or rack.